Converting into human results in imprecise values when specifying bytes
directly, which in turn breaks VMDK image uploads. Instead, just use the
raw bytes value when creating the volume instead of converting it back.
It didn't make any sense to me for mem(prov) to be the default selector,
since this has too many caveats versus mem(free). Switch to using
mem(free) as the default (i.e. "mem") and make memprov the alternative.
Otherwise the node entries could come back in an arbitrary order; since
this is an ordered list of dictionaries that might not be expected by
the API consumers, so ensure it's always sorted.
1. Add documentation on the node selector flags. In the API, reference
the daemon configuration manual which now includes details in this
section; in the CLI, provide the help in "pvc vm define" in detail and
then reference that command's help in the other commands that use this
field.
2. Ensure the naming is consistent in the CLI, using the flag name
"--node-selector" everywhere (was "--selector" for "pvc vm" commands and
"--node-selector" for "pvc provisioner" commands).
Adds commands to both replace an OSD disk, and refresh (reimport) an
existing OSD disk on a new node. This handles the cases where an OSD
disk should be replaced (either due to upgrades or failures) or where a
node is rebuilt in-place and an existing OSD must be re-imported to it.
This should avoid the need to do a full remove/add sequence for either
case.
Also cleans up some aspects of OSD removal that are identical between
methods (e.g. using safe-to-destroy and sleeping after stopping) and
fixes a bug if an OSD does not truly exist when the daemon starts up.
Ensures that information like the FSIDs and the OSD LVM volume are
stored in Zookeeper at creation time and updated at daemon start time
(to ensure the data is populated at least once, or if the /dev/sdX
path changes).
This will allow safer operation of OSD removals and the potential
implementation of re-activation after node replacements.
Allows an administrator to adjust the PG count of a given pool. This can
be used to increase the PGs (for example after adding more OSDs) or
decrease it (to remove OSDs, reduce CPU load, etc.).
Allows specifying a particular device class ("tier") for a given pool,
for instance SSD-only or NVMe-only. This is implemented with Crush
rules on the Ceph side, and via an additional new key in the pool
Zookeeper schema which is defaulted to "default".
Solves two problems:
1. How match fuzziness was used was very inconsistent; make them all the
same, i.e. "if is_fuzzy and limit, apply .* to both sides".
2. Use re.fullmatch instead of re.match to ensure exact matching of the
regex to the value. Without fuzziness, this would sometimes cause
inconsistent behavior, for instance if a limit was non-fuzzy "vm",
expecting to match the actual "vm", but also matching "vm1" too.
Instead of requiring the VM to already be stopped, instead allow disable
state changes to perform a shutdown first. Also add a force option which
will do a hard stop instead of a shutdown.
References #148
Refactors some of the code in VXNetworkInterface to handle MTUs in a
more streamlined fashion. Also fixes a bug whereby bridge client
networks were being explicitly given the cluster dev MTU which might not
be correct. Now adds support for this option explicitly in the configs,
and defaults to 1500 for safety (the standard Ethernet MTU).
Addresses #144
When using the "state", "node", or "tag" arguments to a VM list, add
support for a "negate" flag to look for all VMs *not in* the state,
node, or tag state.
The default of 0.05 (5%) is likely ideal in the initial implementation,
but allow this to be set explicitly for maximum flexibility in
space-constrained or performance-critical use-cases.