Go to file
Joshua Boniface 1038d5c576 Ensure interface is up before bootstrap init 2024-10-17 13:14:52 -04:00
.hooks Initial commit of PVC Bootstrap system 2022-01-02 00:38:02 -05:00
bootstrap-daemon Add OSD count configuration handling 2024-09-23 12:58:49 -04:00
docs Add flow diagram to README 2022-01-04 11:24:34 -05:00
.flake8 Initial commit of PVC Bootstrap system 2022-01-02 00:38:02 -05:00
.gitignore Initial commit of PVC Bootstrap system 2022-01-02 00:38:02 -05:00
LICENSE Initial commit of PVC Bootstrap system 2022-01-02 00:38:02 -05:00
README.md Update description of detect: strings 2024-08-30 11:07:11 -04:00
format Initial commit of PVC Bootstrap system 2022-01-02 00:38:02 -05:00
gen-api-doc Initial commit of PVC Bootstrap system 2022-01-02 00:38:02 -05:00
install-pvcbootstrapd.sh Ensure interface is up before bootstrap init 2024-10-17 13:14:52 -04:00
lint Initial commit of PVC Bootstrap system 2022-01-02 00:38:02 -05:00

README.md

PVC Bootstrap System

The PVC bootstrap system provides a convenient way to deploy PVC clusters. Rather than manual node installation, this system provides a fully-automated deployment from node powering to cluster readiness, based on pre-configured values. It is useful if an administrator will deploy several PVC clusters or for repeated re-deployment for testing purposes.

Setup

Setting up the PVC bootstrap system manually is very complicated, and has thus been automated with an installer script instead of providing a Debian or PIP package.

Preparing to use the PVC Bootstrap system

  1. Prepare a Git repository to store cluster configurations. This can be done automatically with the create-local-repo.sh script in the PVC Ansible repository.

  2. Create group_vars for each cluster you plan to bootstrap. Additionally, ensure you configure the bootstrap.yml file for each cluster with the relevant details of the hardware you will be using. This step can be repeated for each cluster in the future as new clusters are required, and the system will automatically pull changes to the local PVC repository once configured.

Preparing a PVC Bootstrap host

  1. The recommended OS for a PVC Bootstrap host is Debian GNU/Linux 10+. In terms of hardware, there are several supported options:

    i) A small single-board computer with wired Ethernet like a Raspberry Pi on aarch64 (32-bit ARM not supported); at least a Pi model 4 or similar modern system is required; Pi models 1-3 do not support aarch64 or are extremely slow in comparison, especially when building the initial TFTP installer root.

    ii) A small desktop computer on amd64 with at least one wired Ethernet port.

    iii) A VM on amd64 or aarch64 connected to the required networks.

  2. Set up a basic outbound network with Internet access; as detailed below, the installer will take care of the internal bootstrap network, either on a dedicated NIC or vLAN, with this host providing NAT'd access out.

  3. Clone this repository somewhere on the host, for instance to /srv or /home.

  4. Run the ./install-pvcbootstrapd.sh script from the root of the repository to install the PVC Bootstrap system on the host. It will prompt for several configuration parameters. The final steps will take some time (up to 2 hours on a Raspberry Pi 4B) so be patient.

Networking for Bootstrap

When using the pvcbootstrapd system, a dedicated network is required to provide bootstrap DHCP and TFTP to the cluster. This network can either have a dedicated, upstream router that does not provide DHCP, or the network can be routed with network address translation (NAT) through the bootstrap host. By default, the installer will configure the latter automatically using a second NIC separate from the upstream NIC of the bootstrap host, or via a vLAN on top of the single NIC.

In bootstrap mode (as opposed to manual install mode), new nodes are configured with their interfaces as follows:

  • BMC: bootstrap
  • Interface 1 (first among all LOM ports): bootstrap
  • Interface 2+ (all other ports): LACP (802.3ad) bond0

The Bootstrap interfaces do DHCP from the bootstrap host, and are thus responsible for autoconfiguration. The remaining interfaces, in an LACP bond, are used to underlay the various standard PVC networks.

Care must therefore be taken to ensure that the BMC and first lan-on-motherboard interface are connected as vLAN access ports in the bootstrap network, and that the remaining ports have some connectivity along the various configured PVC networks, before proceeding.

Consider the following diagram for reference:

Per-Node Physical Connections

Overall Network Topology

Deploying a Cluster with PVC Bootstrap - Redfish

Redfish is an industry-standard RESTful API for interfacing with the BMC (baseband management controller, or out-of-band network management system) on modern (post ~2015) servers from most vendors, including Dell iDRAC, HP iLO, Cisco CIMC, Lenovo XCC, and Supermicro X10 and newer BMCs. Redfish allows remote management, data collection, and configuration from the BMC in a standardized way across server vendors.

The PVC Bootstrap system is designed to heavily leverage Redfish in its automation. With Redfish, cluster deployment is plug-and-play, with no human input after committing the required configuration and connecting the servers. The steps are thus:

  1. Ensure the cluster configuration hosts entries and group_vars are committed to the local PVC repository, including the BMC MAC addresses, default IPMI credentials, and desired hooks (bootstrap.yml), and all other cluster configurations (base.yml and pvc.yml). Generated configurations (e.g. files) will be automatically committed to the repository.

  2. Connect the network ports as outlined in the above diagrams.

  3. Connect power to the servers, but do not manually power on the servers - Redfish will handle this aspect after characterizing each host, as well as manage boot, RAID array creation (as documented in bootstrap.yml), BIOS configuration, etc.

  4. Wait for the cluster bootstrapping to complete; you can watch the output of the pvcbootstrapd and pvcbootstrapd-worker services on the Bootstrap host to see progress, or configure the system to send webhooks to a remote target (e.g. Slack/Mattermost messages). If supported, the indicator LEDs of the nodes will be lit during setup and will be disabled upon completion to provide a physical indication of the process.

  5. Verify and power off the servers and put them into production; you may need to complete several post-install tasks (for instance setting the production BMC networking via sudo ifup ipmi on each node) before the cluster is completely finished.

Deploying a Cluster with PVC Bootstrap - Non-Redfish

The PVC Bootstrap system can still handle nodes without Redfish support, for instance older servers or those from non-compliant vendors. There is however more manual setup in the process. The steps are thus:

  1. Ensure the cluster configuration hosts entries and group_vars are committed to the local PVC repository, including the BMC MAC addresses, default IPMI credentials, and desired hooks (bootstrap.yml), and all other cluster configurations (base.yml and pvc.yml). Generated configurations (e.g. files) will be automatically committed to the repository. Ensure you set redfish: no in the appropriate section of the bootstrap.yml file; the BMC credentials can be empty but the variables must exist.

  2. Do not (yet) connect network ports.

  3. Connect power to the servers and power them on.

  4. Perform any required configuration of BIOS settings, hardware RAID arrays for the system disk, etc.

  5. Power off the servers.

  6. Create a set of host configuration files in the TFTP host directory on the PVC controller, by default at /srv/pvc/tftp/host, one per node. You will need to know the MAC address of the first ethernet (bootstrap network) port of each node to correctly set the filename. Some example contents for the two files are shown below.

  7. Connect the network ports as outlined in the above diagrams.

  8. Power on the servers and set them to boot temporarily (one time) from PXE.

  9. Wait for the cluster bootstrapping to complete; you can watch the output of the pvcbootstrapd and pvcbootstrapd-worker services on the Bootstrap host to see progress, or configure the system to send webhooks to a remote target (e.g. Slack/Mattermost messages). If supported, the indicator LEDs of the nodes will be lit during setup and will be disabled upon completion to provide a physical indication of the process.

  10. Verify and power off the servers and put them into production; you may need to complete several post-install tasks (for instance setting the production BMC networking via sudo ifup ipmi on each node) before the cluster is completely finished.

host-MAC.ipxe

#1ipxe

# The name of this file is "host-123456abcdef.ipxe", where "123456abcdef" is the MAC address of the
# server's Bootstrap Ethernet port (on-motherboard port 1), without spaces or punctuation.

# ARGUMENTS are any additional kernel command line arguments that might be needed for installer boot
# For instance, on an HP DL360 G6 the serial console is ttyS1 at 115200 baud, so the line would be:
#   set imgargs-host console=ttyS1,115200n

# If no additional arguments are required, then this file is optional, or you can set an empty
# imaargs-host value.

set imgargs-host ARGUMENTS

host-MAC.preseed

# The name of this file is "host-123456abcdef.preseed", where "123456abcdef" is the MAC address of the
# server's Bootstrap Ethernet port (on-motherboard port 1), without spaces or punctuation.

# This file defines the various configuration options to preseed the installer. An example here shows
# the various options, but what to put depends on the exact configuration of pvcbootstrapd. This
# information is, under Redfish, populated automatically based on the information provided in the
# cluster "bootstrap.yml" group vars file.

# Any option not set explicitly here is not set by the bootstrap system by default and should not need
# to be changed by the administrator.

# This BASH-compliant variables file is Loaded during PXE installs to preseed the environment.
# During normal usage, the pvcbootstrapd will load this file, adjust it according to its needs,
# and write out one instance per node to be installed.
#
# This file is thus not designed to be used by humans, and its values are seeded via options in
# the cluster-local Ansible group_vars, though it can be used as a manual template if required.

###
### General definitions/overrides
###
# The Debian release to use (overrides the default)
debrelease="bullseye"

# The Debian mirror to use (overrides the default)
debmirror="http://ftp.debian.org/debian"

# Additional packages (comma-separated) to install in the base system
addpkglist="ca-certificates"

# Alternate filesystem for system volumes (/, /var/lib/ceph, /var/lib/zookeeper)
filesystem="ext4"


###
### Per-host definitions (required)
###

# The hostname of the system (set per-run)
target_hostname="hv1.example.tld"

# The target system disk path; must be a single disk (mdadm/software RAID is not supported)
# This will usually use a `detect` string. A "detect" string is a string in the form "detect:<NAME>:<HUMAN-SIZE>:<ID>".
# Detect strings allow for automatic determination of Linux block device paths from known basic information
# about disks by leveraging "lsscsi"/"nvme" on the target host.
# The "NAME" should be some descriptive identifier that would be part of the device's Model information, for instance
# the manufacturer (e.g. "INTEL") or a similar unique string (e.g. "BOSS" for Dell BOSS cards).
# The "HUMAN-SIZE" should be the labeled human-readable size of the device (e.g. "480GB", "1.92TB").
# The "ID" specifies the Nth 0-indexed device which matches the NAME" and "HUMAN-SIZE" values (e.g. "2" would match the
# third device with the corresponding "NAME" and "HUMAN-SIZE").
# When matching against sizes, there is +/- 3% flexibility to account for base-1000 vs. base-1024 differences and
# rounding errors.
# The "NAME" may contain whitespace but if so the entire detect string should be quoted, and is case-insensitive.
target_disk="detect:LOGICAL:146GB:0"

# SSH key fetch method (usually tftp)
target_keys_method="tftp"

# SSH key fetch path (usually keys.txt)
target_keys_path="keys.txt"

# Deploy username (usually deploy)
target_deploy_user="deploy"

# Consoles to use by the inital boot process; these are normally set automatically
# based on the TTYs found by the installer, and are later overridden by the Ansible
# playbooks based on the hardware configuration. It is best to leave this commented
# unless you know that you need it.
#target_consoles="console=tty1 console=ttyS1,115200"

# Modules to blacklist from the installed system; we include hpwdt (HP Proliant
# watchdog) by default since this is known to cause kernel panics on boot with this
# hardware. Add others here too if you wish to add more to the default.
#target_module_blacklist=( "hpwdt" )

# Installer checkin URI (provided by pvcbootstrapd)
pvcbootstrapd_checkin_uri="http://10.255.255.1:9999/checkin/host"

Bootstrap Process

This diagram outlines the various states the nodes and clusters will be in throughout the setup process along with the individual steps for reference. Which node starts characterizing first can be random, but is shown as node1 for clarity. For non-Redflish installs, the first several steps must be completed manually as referenced above.

PVC Bootstrap Process