Joshua Boniface
414678f683
Fix a few more extraneous splits
...
Just use this_node if applicable, or the raw node.hostname.
2021-11-11 17:35:42 -05:00
Joshua Boniface
b24e539252
Remove extraneous splits
...
The node.hostname should always be short.
2021-11-11 17:31:56 -05:00
Joshua Boniface
243c910d6d
Unify and standardize inventory_hostname
...
This was causing some confusing conflicts, so create a new fact called
"this_node" which is inventory_hostname.split('.')[0], i.e. the short
name, and use that everywhere instead of an FQDN or true inventory
hostname.
2021-11-11 17:19:03 -05:00
Joshua Boniface
70c7c76605
Move pvc maintenance to separate plays
...
This ensures that the maintenance on/off happens before all tasks and
after all tasks and not intermittently.
2021-11-11 15:54:22 -05:00
Joshua Boniface
fed71d7add
Add option for setting CPU governor
...
Allows the administrator to set a CPU frequency governor if they need
to, though the default of ondemand is usually sufficient.
2021-11-08 00:21:58 -05:00
Joshua Boniface
dd60b6b9ea
Fix name of IPMI check again
2021-11-02 22:21:16 -04:00
Joshua Boniface
99682c16a2
Fix name of ipmi check
2021-11-02 22:16:47 -04:00
Joshua Boniface
319ca891d5
Add IPMI check to tasks
2021-11-02 22:04:51 -04:00
Joshua Boniface
b7bca571a8
Adjust headers and add LOM check
2021-11-02 22:04:27 -04:00
Joshua Boniface
bd98fdfbd8
Add node list to PVC MOTD
2021-11-02 22:04:27 -04:00
Joshua Boniface
820e2a64d0
Ignore errors during flush commands
...
These might inexplicably fail, but that is fine.
2021-10-13 10:34:36 -04:00
Joshua Boniface
079013dfbc
Fix whitespaced manufacturer and bad [[
2021-10-11 15:08:04 -04:00
Joshua Boniface
8c3b5d7dab
Add coordinator state to MOTD
2021-10-11 15:05:01 -04:00
Joshua Boniface
cb6199ef0d
Support unknown manufacturers in MOTD
2021-10-11 14:59:55 -04:00
Joshua Boniface
34a016bdac
Ignore errors restarting libvirtd
...
This seems to inexplicably fail sometimes. We can just ignore it.
2021-10-11 14:47:04 -04:00
Joshua Boniface
739c60fce0
Add resolv.conf customization
2021-10-11 14:41:29 -04:00
Joshua Boniface
5e83f1826e
Add note about moving files up
2021-10-10 05:42:01 -04:00
Joshua Boniface
bc99c0b7cc
Revert "Add symlink for Ceph file pickup"
...
This reverts commit 3ac946bf2e
.
2021-10-10 05:41:55 -04:00
Joshua Boniface
3ac946bf2e
Add symlink for Ceph file pickup
2021-10-10 05:23:25 -04:00
Joshua Boniface
2c80c187c3
Include another upgrade in deb11 playbook
...
Ensures that the system is fully updated after re-enabling the security
repository during the base run.
2021-10-10 05:10:57 -04:00
Joshua Boniface
704e88dca4
Add Debian 10 -> Debian 11 upgrade playbook
2021-10-10 05:07:56 -04:00
Joshua Boniface
39dd430792
Include pvc-installer in create repo update script
2021-10-10 05:04:48 -04:00
Joshua Boniface
b009012cb8
Add pvc-installer to create-local-repo script
2021-10-10 04:56:16 -04:00
Joshua Boniface
8c0b174da1
Add create-local-repo.sh script
2021-10-10 04:50:11 -04:00
Joshua Boniface
3f4ddc35d0
Update README for Ansible vers and Debian vers
2021-10-10 04:22:17 -04:00
Joshua Boniface
3de777a036
Disable unified cgroup heirarchy on kernel cmdline
...
This is required on Debian 11 to use the cset tool, since the newer
systemd implementation of a unified cgroup hierarchy is not compatible
with the cset tool.
Ref for future use:
https://github.com/lpechacek/cpuset/issues/40
2021-10-10 03:44:13 -04:00
Joshua Boniface
f0f3960250
Use inventory_hostname in IPMI fragment
2021-10-10 02:57:54 -04:00
Joshua Boniface
5ab40fa15f
Update bondX configuration
2021-10-10 02:31:47 -04:00
Joshua Boniface
2c0e09f657
Add setting bridge_mtu to config
2021-10-09 19:29:22 -04:00
Joshua Boniface
74066e6ceb
Avoid errors if noout fails
2021-10-07 16:31:52 -04:00
Joshua Boniface
859cfbb51e
Add smartmontools to base package list
2021-10-07 15:18:45 -04:00
Joshua Boniface
5797535997
Adjust documentation and behaviour of cpuset
...
1. Detail the caveats and specific situations and ref the documentation
which will provide more details.
2. Always install the configs, but use /etc/default/ceph-osd-cpuset to
control if the script does anything or not (so, the "osd" cset set is
always active just not set in a special way.
2021-09-29 20:49:00 -04:00
Joshua Boniface
81cf341c32
Install cset configs even if disabled
...
The setup script handles this instead.
2021-09-29 10:23:01 -04:00
Joshua Boniface
645249b57e
Allow dynamic enabling/disabling of cset
...
Add a separate config to handle enable/disable on the system itself.
2021-09-29 10:21:47 -04:00
Joshua Boniface
8ac2a5ea0c
Adjust default ceph.conf parameters
...
1. Remove an explicit OSD journal size, especially such a small one (no
clue why I ever added that...)
2. Add max scrubs, disable scrub during recovery, and set scrub sleep.
3. Add max backfills, tune recovery sleep to 0 to prioritize recovery.
2021-09-28 02:09:50 -04:00
Joshua Boniface
732bfe732c
Add Ceph OSD cpuset tuning options
...
Allows an administrator to set CPU pinning with the cpuset tool for Ceph
OSDs, in situations where CPU contention with VMs or other system tasks
may be negatively affecting OSD performance. This is optional, advanced
tuning and is disabled by default.
2021-09-27 00:27:57 -04:00
Joshua Boniface
d7b07925bb
Fix bad flag
2021-09-09 13:07:15 -04:00
Joshua Boniface
de64437ff6
Add interpreter var to sites group
2021-09-09 13:04:50 -04:00
Joshua Boniface
77c84cec52
Add package installs for different Debian versions
2021-09-09 12:59:18 -04:00
Joshua Boniface
a91112fa71
Move paths and keys to defaults
2021-08-24 15:25:42 -04:00
Joshua Boniface
2e9d02ab52
Add additional CMK checks
2021-08-21 15:41:44 -04:00
Joshua Boniface
9b103f48ad
Update default repo domain
...
We now have parallelvirtualcluster.org set up, so use that instead of
the bonifacelabs domain.
2021-08-21 01:00:53 -04:00
Joshua Boniface
b37d6c3009
Wait longer when restarting services
...
From 15 -> 30 seconds to ensure more time for stabilization before
proceeding with the next.
2021-07-30 11:46:49 -04:00
Joshua Boniface
b62731199f
Add default features flag to ceph.conf generator
...
Coupled with the removal of explicit --image-features flags to the RBD
command in PVC itself, this ensures that only the two features supported
on kernel 4.19 are enabled by default.
2021-07-30 11:39:24 -04:00
Joshua Boniface
2cc4548af6
Fix sources.list for Bullseye
2021-07-26 00:36:39 -04:00
Joshua Boniface
311f388f56
Increase flush/unflush wait timeout
...
Bump this from 10 minutes (60 * 10 seconds) to 30 minutes (180 * 10
seconds) to ensure there is sufficient time for (relatively) large VMs
to migrate with (relatively) slow networking.
2021-07-22 16:16:27 -04:00
Joshua Boniface
942743daef
Use wait on secondary and delay for 15 seconds
2021-07-22 09:35:00 -04:00
Joshua Boniface
01020ab29c
Rename Daemon upgrade playbook to match
2021-07-22 09:34:26 -04:00
Joshua Boniface
dd2fe47881
Typo fix
2021-07-20 13:59:47 -04:00
Joshua Boniface
9e42e6ae88
Lower autopurge interval to 1 hour
2021-07-20 13:57:59 -04:00