parent
cfbe724458
commit
c9393ba957
|
@ -1,17 +1,69 @@
|
|||
---
|
||||
# Basic information
|
||||
# Cluster domain for node FQDNs
|
||||
local_domain: upstream.local
|
||||
|
||||
# IPMI user and password
|
||||
# > For the password, use pwgen to generate.
|
||||
# > Set these in the IPMI configuration as a user with permissions to reboot the host.
|
||||
username_ipmi_host: pvc
|
||||
passwd_ipmi_host: "" # Use pwgen to generate (set in IPMI config)
|
||||
passwdhash_root: "" # Use pwgen to generate and openssl passwd -1 -salt xyz <pw> to hash
|
||||
# Logrotate
|
||||
passwd_ipmi_host: ""
|
||||
|
||||
# Root user password (as /etc/shadow hash)
|
||||
# > Use pwgen to generate and openssl passwd -1 -salt xyz <pw> to hash.
|
||||
passwdhash_root: ""
|
||||
|
||||
# Log rotation configuration
|
||||
logrotate_keepcount: 7
|
||||
logrotate_interval: daily
|
||||
# Email
|
||||
|
||||
# Root email name (usually "root")
|
||||
username_email_root: root
|
||||
# Administrative users
|
||||
|
||||
# Administrative shell users for the cluster
|
||||
admin_users:
|
||||
- name: "myuser"
|
||||
uid: 500
|
||||
keys:
|
||||
- "ssh-ed25519 MyKey 2019-06"
|
||||
|
||||
# Node network definitions (used by /etc/network/interfaces and PVC)
|
||||
# > The "type" can be one of three NIC types: "nic" for raw NIC devices, "bond" for ifenslave bonds,
|
||||
# or "vlan" for vLAN interfaces. The PVC role will write out an interfaces file matching these specs.
|
||||
# > Three names are reserved for the PVC-specific interfaces: upstream, cluster, and storage; others
|
||||
# may be used at will to describe the other devices.
|
||||
# > All devices should be using the newer device name format (i.e. enp1s0f0 instead of eth0).
|
||||
# > In this example configuration, the "upstream" device is an LACP bond of the first two onboard NICs,
|
||||
# with the two other PVC networks being vLANs on top of this device.
|
||||
# > Usually, the Upstream network provides Internet connectivity for nodes in the cluster, and all
|
||||
# nodes are part of it regardless of function for this reason; an optional, advanced, configuration
|
||||
# will have only coordinators in the upstream network, however this configuration is out of the scope
|
||||
# of this role.
|
||||
networks:
|
||||
"upstream":
|
||||
device: "bondU"
|
||||
type: "bond"
|
||||
bond_mode: "802.3ad"
|
||||
bond_devices:
|
||||
- "enp1s0f0"
|
||||
- "enp1s0f1"
|
||||
mtu: 1500
|
||||
domain: "{{ local_domain }}"
|
||||
subnet: "192.168.100.0/24"
|
||||
floating_ip: "192.168.100.10/24"
|
||||
gateway_ip: "192.168.100.1"
|
||||
"cluster":
|
||||
device: "vlan1001"
|
||||
type: "vlan"
|
||||
raw_device: "bondU"
|
||||
mtu: 1500
|
||||
domain: "pvc-cluster.local"
|
||||
subnet: "10.0.0.0/24"
|
||||
floating_ip: "10.0.0.254/24"
|
||||
"storage":
|
||||
device: "vlan1002"
|
||||
type: "vlan"
|
||||
raw_device: "bondU"
|
||||
mtu: 1500
|
||||
domain: "pvc-storage.local"
|
||||
subnet: "10.0.1.0/24"
|
||||
floating_ip: "10.0.1.254/24"
|
||||
|
|
|
@ -1,7 +1,16 @@
|
|||
---
|
||||
# Logging
|
||||
pvc_log_to_file: True
|
||||
pvc_log_to_stdout: True
|
||||
pvc_log_keepalives: True
|
||||
pvc_log_keepalive_cluster_details: True
|
||||
pvc_log_keepalive_storage_details: True
|
||||
pvc_log_console_lines: 1000
|
||||
|
||||
# Ceph storage
|
||||
pvc_ceph_storage_secret_uuid: "" # Use uuidgen to generate
|
||||
# Database
|
||||
|
||||
# Database configurations
|
||||
pvc_dns_database_name: "pvcdns"
|
||||
pvc_dns_database_user: "pvcdns"
|
||||
pvc_dns_database_password: "" # Use pwgen to generate
|
||||
|
@ -9,7 +18,17 @@ pvc_replication_database_user: "replicator"
|
|||
pvc_replication_database_password: "" # Use pwgen to generate
|
||||
pvc_superuser_database_user: "postgres"
|
||||
pvc_superuser_database_password: "" # Use pwgen to generate
|
||||
# Coordinators
|
||||
|
||||
# Network routing configuration
|
||||
# > The ASN should be a private ASN number.
|
||||
# > The list of routers are those which will learn routes to the PVC client networks via BGP;
|
||||
# they should speak BGP and allow sessions from the PVC nodes.
|
||||
pvc_asn: "65500"
|
||||
pvc_routers:
|
||||
- "192.168.100.1"
|
||||
|
||||
# Node list
|
||||
# > Every node configured with this playbook must be specified in this list.
|
||||
pvc_nodes:
|
||||
- hostname: "pvchv1"
|
||||
is_coordinator: yes
|
||||
|
@ -50,30 +69,22 @@ pvc_nodes:
|
|||
ipmi_host: "pvchv3-lom.{{ local_domain }}"
|
||||
ipmi_user: "{{ username_ipmi_host }}"
|
||||
ipmi_password: "{{ passwd_ipmi_host }}"
|
||||
# Networks
|
||||
pvc_asn: "65500"
|
||||
pvc_routers:
|
||||
- "192.168.100.1"
|
||||
pvc_upstream_device: "enp1s0f0" # Set to your actual NIC device (or bond, vLAN, etc.)
|
||||
pvc_upstream_mtu: "1500"
|
||||
pvc_upstream_domain: "{{ local_domain }}"
|
||||
pvc_upstream_subnet: "192.168.100.0/23"
|
||||
pvc_upstream_floatingip: "192.168.100.10/23"
|
||||
pvc_upstream_gatewayip: "192.168.100.1"
|
||||
pvc_cluster_device: "vlan1001" # Set to your actual NIC device (usually a vLAN)
|
||||
pvc_cluster_mtu: "1500"
|
||||
pvc_cluster_domain: "pvc.local"
|
||||
pvc_cluster_subnet: "10.0.0.0/24"
|
||||
pvc_cluster_floatingip: "10.0.0.254/24"
|
||||
pvc_storage_device: "vlan1002" # Set to your actual NIC device (usually a vLAN)
|
||||
pvc_storage_mtu: "1500"
|
||||
pvc_storage_domain: "pvc.storage"
|
||||
pvc_storage_subnet: "10.0.1.0/24"
|
||||
pvc_storage_floatingip: "10.0.1.254/24"
|
||||
# Logging
|
||||
pvc_log_to_file: True
|
||||
pvc_log_to_stdout: True
|
||||
pvc_log_keepalives: True
|
||||
pvc_log_keepalive_cluster_details: True
|
||||
pvc_log_keepalive_storage_details: True
|
||||
pvc_log_console_lines: 1000
|
||||
|
||||
# Configuration file networks
|
||||
# > Taken from base.yml's configuration; do not modify this section.
|
||||
pvc_upstream_device: "{{ networks['upstream']['device'] }}"
|
||||
pvc_upstream_mtu: "{{ networks['upstream']['mtu'] }}"
|
||||
pvc_upstream_domain: "{{ networks['upstream']['domain'] }}"
|
||||
pvc_upstream_subnet: "{{ networks['upstream']['subnet'] }}"
|
||||
pvc_upstream_floatingip: "{{ networks['upstream']['floating_ip'] }}"
|
||||
pvc_upstream_gatewayip: "{{ networks['upstream']['gateway_ip'] }}"
|
||||
pvc_cluster_device: "{{ networks['cluster']['device'] }}"
|
||||
pvc_cluster_mtu: "{{ networks['cluster']['mtu'] }}"
|
||||
pvc_cluster_domain: "{{ networks['cluster']['domain'] }}"
|
||||
pvc_cluster_subnet: "{{ networks['cluster']['subnet'] }}"
|
||||
pvc_cluster_floatingip: "{{ networks['cluster']['floating_ip'] }}"
|
||||
pvc_storage_device: "{{ networks['storage']['device'] }}"
|
||||
pvc_storage_mtu: "{{ networks['storage']['mtu'] }}"
|
||||
pvc_storage_domain: "{{ networks['storage']['domain'] }}"
|
||||
pvc_storage_subnet: "{{ networks['storage']['subnet'] }}"
|
||||
pvc_storage_floatingip: "{{ networks['storage']['floating_ip'] }}"
|
||||
|
|
|
@ -196,6 +196,22 @@
|
|||
# System configuration
|
||||
#
|
||||
|
||||
# networking
|
||||
- name: install base interfaces file
|
||||
template:
|
||||
src: etc/network/interfaces.j2
|
||||
dest: /etc/network/interfaces
|
||||
tags: network
|
||||
|
||||
- name: install per-interface files
|
||||
template:
|
||||
src: etc/network/interfaces-perif.j2
|
||||
dest: /etc/network/interfaces.d/{{ network.key }}
|
||||
with_dict: "{{ networks }}"
|
||||
loop_control:
|
||||
loop_var: network
|
||||
tags: network
|
||||
|
||||
# capabilities
|
||||
- name: set ping capabilities
|
||||
capabilities:
|
||||
|
|
|
@ -0,0 +1,13 @@
|
|||
# PVC node interface-specific interface file - {{ network.key }}
|
||||
# {{ ansible_managed }}
|
||||
|
||||
auto {{ network.value['device'] }}
|
||||
iface {{ network.value['device'] }} inet manual
|
||||
post-up ip link set $IFACE mtu {{ network.value['mtu'] }}
|
||||
{% if network.value['type'] == 'bond' %}
|
||||
bond_mode {{ network.value['bond_mode'] }}
|
||||
slaves {% for device in network.value['bond_devices'] %}{{ device }} {% endfor %}
|
||||
{% endif %}
|
||||
{% if network.value['type'] == 'vlan' %}
|
||||
vlan_raw_device {{ network.value['raw_device'] }}
|
||||
{% endif %}
|
|
@ -0,0 +1,10 @@
|
|||
# PVC node interfaces file
|
||||
# {{ ansible_managed }}
|
||||
|
||||
# Loopback interface
|
||||
auto lo
|
||||
iface lo inet loopback
|
||||
iface lo inet6 loopback
|
||||
|
||||
# Include directory
|
||||
source-directory /etc/network/interfaces.d
|
Loading…
Reference in New Issue