# PVC Ansible `group_vars`
|
||||
|
||||
1. There should always be at least two (2) files here, with an optional third (3rd):
|
||||
|
||||
* `base.yml`: Specifies basic cluster information.
|
||||
|
||||
* `pvc.yml`: Specifies PVC system information.
|
||||
|
||||
* `bootstrap.yml`: Specifies `pvcbootstrapd` deployment information (optional).
|
||||
|
||||
2. The files can be named arbitrarily, but these named are highly recommended. If the names are changed, and you use `pvcbootstrapd`, ensure you set them properly in its configuration.
|
||||
|
||||
These files are self-documented; read the comments carefully.
|
|
@ -0,0 +1,202 @@
|
|||
---
|
||||
# PVC cluster specification for pvcbootstrapd
|
||||
#
|
||||
# This configuration is entirely optional, and is not required unless you are using pvcbootstrap to
|
||||
# deploy the cluster. It must be filled out and committed before connecting any hosts from
|
||||
# the new cluster.
|
||||
#
|
||||
# Bootstrap Host Definitions
|
||||
#
|
||||
# All hosts to be bootstrapped by the pvcbootstrapd system must be present in this list.
|
||||
#
|
||||
# NOTE: Only Redfish-capable BMCs can be automatically provisionned by pvcbootstrapd. Non-Redfish
|
||||
# BMCs can be used, but they must be pre-configured with a system disk RAID, to boot from network,
|
||||
# etc. and the per-host TFTP files must be created manually.
|
||||
#
|
||||
# Disks Logic
|
||||
#
|
||||
# There are 3 categories of disks that can be specified for use in the pvcbootstrapd system:
|
||||
# * System disk (for the host OS)
|
||||
# * Data disks (for VM data, i.e. Ceph OSDs)
|
||||
# * Ceph database disk (if applicable, for OSD journaling/database)
|
||||
#
|
||||
# The first two categories are not optional; at least one system disk and one data disk per
|
||||
# coordinator node must be specified for a usable cluster.
|
||||
#
|
||||
# OSD Database Disks
|
||||
#
|
||||
# OSD database disks are optional, and only required in some specific situations with some specific
|
||||
# guest workloads. Only one (1) device may be specified, and this should usually be an NVMe device
|
||||
# with a Linux path (e.g. '/dev/nvme0n1', see format specifications below).
|
||||
#
|
||||
# The post-bootstrap hooks will use this disk, if present, to create an "osd-db-vg" device within
|
||||
# PVC before creating OSDs, and this database VG will then be used for all OSDs on the node.
|
||||
#
|
||||
# Data Disks
|
||||
#
|
||||
# At least one (1) data disk must be specified, and these should be fast devices (SATA, SAS, or
|
||||
# NVMe SSD); the former two can use any format below, but the latter should use a Linux path.
|
||||
#
|
||||
# These disk(s) will be used for OSD volumes within PVC, and will be provisioned by the post-
|
||||
# bootstrap hooks.
|
||||
#
|
||||
# System Disks
|
||||
#
|
||||
# At least one (1) and at most two (2) system disks must be specified, and these can be any
|
||||
# devices (SSDs, SD Cards, etc.), though faster system disks will result in a more responsive
|
||||
# system.
|
||||
#
|
||||
# If one system disk is specified, the system will be installed directly onto it.
|
||||
#
|
||||
# If two system disks are specified, and the controller supports it, a hardware RAID will be
|
||||
# created out of the disks for use as the resulting single system disk.
|
||||
#
|
||||
# PVC does not supports software RAID for node system disks; of the controller does not support
|
||||
# Redfish and hardware RAID therein, only the first listed disk will be used.
|
||||
#
|
||||
# Drive Specification Formats
|
||||
#
|
||||
# The disks in each group can be specified in one of 3 ways:
|
||||
#
|
||||
# 1. A full Linux block path beginning with '/dev/'. Any path can be used but, if possible,
|
||||
# reliable paths like '/dev/disk/by-path' or '/dev/disk/by-id' are recommended unless there is
|
||||
# no chance for ambiguity (e.g. only a single sdX drive is present for the system disk).
|
||||
#
|
||||
# These direct paths are the most reliable way to specify NVMe disks due to the predicable
|
||||
# format of Linux "/dev/nvmeX" drive names.
|
||||
#
|
||||
# 2. On Redfish-capable hosts only, a chassis disk ID number, usually 0-7 (0-indexed), indicating
|
||||
# the position of the disk on the primary storage controller. When specified this way, the
|
||||
# system will query the active storage devices from Redfish and then automatically construct
|
||||
# a "detect:" string for each one based on its vendor/model, size and ID.
|
||||
#
|
||||
# Note that on most chassis, the bays are labeled "1-8"; these must be converted by
|
||||
# subtracting 1 from them to get 0-indexed IDs. So for example the drive in bay "1" would
|
||||
# have the index of 0, and so on.
|
||||
#
|
||||
# These ID numbers are the most relible way to specify SATA/SAS disks on Redfish-capable
|
||||
# nodes and should be preferred for their simplicity there.
|
||||
#
|
||||
# The pvcbootstrapd setup will use the values provided by Redfish to craft a "detect:" string
|
||||
# for the block device (or virtual RAID array, if two devices are specified for the system
|
||||
# disk entries).
|
||||
#
|
||||
# 3. A "detect:" string. This is a specially-formatted string which can be used by the installer
|
||||
# to search the output of 'lsscsi' for the given device. A "detect:" string is formatted as
|
||||
# such:
|
||||
# detect:<Controller-or-Model-Name>:<0-indexed-ID>:<Capacity-in-human-units>
|
||||
#
|
||||
# For example, to detect the *second* 800GB Intel SSD:
|
||||
# detect:INTEL:1:800GB
|
||||
# Or to detect a (single) Dell BOSS card's virtual RAID-1 of two 240GB M.2 SSDs:
|
||||
# detect:DELLBOSS:0:240GB
|
||||
# Or to detect the first RAID-1 volume on a Dell PERC controller of two 200GB SSDs:
|
||||
# detect:PERC:0:200GB
|
||||
#
|
||||
# The controller/vendor name will usually be fully capitalized. This string can contain
|
||||
# multiple space-separated elements, though usually only the first word is required, for
|
||||
# example "DELLBOSS VD" -> "DELLBOSS" or "PERC H330 Mini" -> "PERC", unless there is
|
||||
# potential for ambiguity.
|
||||
#
|
||||
# The ID is the Nth entry *of multiple identical devices*, and should usually be "0" unless
|
||||
# there are multiple identically-sized devices with the same vendor. If there is only a set
|
||||
# of identical drives, these will usually match in position to the drive bay because they will
|
||||
# be sorted by the PCIe bus identifier, but this does not map 1-to-1 with chassis disk IDs as
|
||||
# used by specification format 2, and must always be 0-indexed based on a given vendor+size.
|
||||
#
|
||||
# The size should be the expected human-readable size of the disk with a suffix attached, for
|
||||
# example "800GB", "240GB", "1.92TB", "2TB", etc.. This value will be used to match, within
|
||||
# +/-2%, the actual reported sizes of the block devices (which are usually slightly smaller).
|
||||
#
|
||||
# These "detect:" strings are the most reliable way to determine a SATA/SSD disk or hardware
|
||||
# RAID volume independent of Redfish, and should generally be used for these device types on
|
||||
# non-Redfish capable systems. NVMe devices can *not* use this format and should always use
|
||||
# the predicable '/dev/nvmeX' names instead as mentioned in specification format 1.
|
||||
|
||||
bootstrap:
|
||||
# First node
|
||||
"d8:d7:d6:d5:d4:d1": # BMC MAC Address (from asset tag, etc.)
|
||||
node: # Node information
|
||||
hostname: hv1 # The (short) hostname. Must be present in the pvc_nodes list.
|
||||
config: # Node configuration (optional)
|
||||
kernel_options: # Additional options for the installer kernel command line
|
||||
- "console=ttyS1,115200n"
|
||||
release: buster # The Debian release to install, OPTIONAL
|
||||
mirror: http://ftp.debian.org # The Debian mirror to use, OPTIONAL
|
||||
packages: # List of additional packages to install, OPTIONAL
|
||||
- ca-certificates
|
||||
filesystem: ext4 # The filesystem to use for the system partitions, OPTIONAL
|
||||
|
||||
bmc:
|
||||
username: Administrator # BMC/IPMI administrative username
|
||||
password: SuperSecret # BMC/IPMI administrative password (initial)
|
||||
# NOTE: This is usually the out-of-box password; the actual
|
||||
# password will be set later by the Ansible roles.
|
||||
redfish: yes # Can system BMC support Redfish?
|
||||
bios_settings: # An optional listing of BIOS settings to alter before bootstrap
|
||||
BootMode: "Uefi" # NOTE: Must be valid Redfish BIOS options or will be ignored.
|
||||
SecureBoot: "Disabled"
|
||||
disks: # Disk definitions (see explanations above)
|
||||
system: # List of system disk(s)
|
||||
- "/dev/disk/by-path/pci-0000:41:00.0-ata-1"
|
||||
data: # List of data disks for OSDs
|
||||
- "/dev/disk/by-path/pci-0000:01:00.0-sas-phy0-lun-0"
|
||||
- "/dev/disk/by-path/pci-0000:01:00.0-sas-phy4-lun-0"
|
||||
osd_db: # List of OSD database disk (maximum one)
|
||||
- "/dev/nvme0n1"
|
||||
# Second node
|
||||
"d8:d7:d6:d5:d4:d2":
|
||||
node:
|
||||
hostname: hv2
|
||||
config:
|
||||
bmc:
|
||||
username: Administrator
|
||||
password: SuperSecret
|
||||
redfish: yes
|
||||
disks:
|
||||
system:
|
||||
- "detect:DELLBOSS:0:240GB"
|
||||
data:
|
||||
- "detect:INTEL:0:960GB"
|
||||
- "detect:INTEL:1:960GB"
|
||||
# Third node
|
||||
"d8:d7:d6:d5:d4:d3":
|
||||
node:
|
||||
hostname: hv3
|
||||
config:
|
||||
bmc:
|
||||
username: Administrator
|
||||
password: SuperSecret
|
||||
redfish: no
|
||||
disks:
|
||||
system:
|
||||
- "/dev/sda"
|
||||
data:
|
||||
- "/dev/nvme0n1"
|
||||
- "/dev/nvme0n2"
|
||||
|
||||
#
|
||||
# Hooks
|
||||
#
|
||||
# Hooks are sets of tasks (commands, etc.) to be run against the cluster once the bootstrap Ansible run has
|
||||
# been completed. These are useful to perform post-Ansible setup tasks, for instance creating storage OSDs and
|
||||
# pools, deploying VMs, running hooks, executing webhooks, etc.
|
||||
#
|
||||
# Each hook can define which host(s) it should be run on or against depending on the handler.
|
||||
# There are several fixed, defined hooks which are known to the cluster, while all other hooks must be defined
|
||||
# with their full specifications.
|
||||
#
|
||||
# The hook type can be one of the defined hooks, "pvc", "script", "python", or "webhook".
|
||||
# * "pvc" hooks use the PVC CLI on one node to execute the desired command, without the leading "pvc".
|
||||
# * "script" hooks are a set of shell commands that will be run in a ROOT shell on the given node(s).
|
||||
# * "python" hooks are a set of Python commands that will be run in a ROOT interpreter on the given node(s).
|
||||
# * "webhook" hooks send POST events with the specified body to the specified URL from pvcprovisionerd itself.
|
||||
#
|
||||
# Hooks are always executed in the order they are presented.
|
||||
hooks:
|
||||
- name: install virtual router
|
||||
type: script
|
||||
node: hv1
|
||||
action: |
|
||||
pvc provisioner profile list
|
||||
|