@@ -121,6 +121,7 @@ sensor:
return tvoc;
unit_of_measurement: "µg/m³"
accuracy_decimals: 0
update_interval: 15s
- platform: template
name: "SGP41 TVOC (ppb)"
@@ -132,6 +133,7 @@ sensor:
return tvoc_ppm;
unit_of_measurement: "ppb"
accuracy_decimals: 0
update_interval: 15s
- platform: template
name: "SGP41 eCO2 (appr.)"
@@ -144,6 +146,7 @@ sensor:
return eco2_ppm;
unit_of_measurement: "ppm"
accuracy_decimals: 0
update_interval: 15s
- platform: sht4x
temperature:
@@ -187,6 +190,39 @@ sensor:
return (b * alpha) / (a - alpha);
update_interval: 15s
- platform: template
name: "Room Health Score"
id: room_health_score
unit_of_measurement: "%"
icon: mdi:home-heart
lambda: |-
float voc_index = id(sgp41_voc_index).state;
float temp = id(sht45_temperature).state;
float humidity = id(sht45_humidity).state;
// VOC Score (0100)
float voc_score = 0;
if (voc_index <= 100) voc_score = 100;
else if (voc_index <= 200) voc_score = 80;
else if (voc_index <= 300) voc_score = 60;
else if (voc_index <= 400) voc_score = 40;
else if (voc_index <= 500) voc_score = 50;
else voc_score = 0;
// Temperature Score (0100)
float temp_score = 100.0 - abs(temp - 23.0) * 10.0;
if (temp_score < 0) temp_score = 0;
// Humidity Score (0100), ideal range 3555%
float humidity_score = 100.0 - abs(humidity - 50.0) * 3.0;
if (humidity_score < 0) humidity_score = 0;
// Weighted average
float overall_score = (voc_score * 0.5 + temp_score * 0.25 + humidity_score * 0.25);
return (int) round(overall_score);
update_interval: 15s
- platform: wifi_signal
name: "WiFi Signal"