This seems like a super-gross way to do this, but at the moment
I don't have a better way. Maybe just remove this component since
none of the volume/snapshot stuff is dynamic; will see as this
progresses.
Prevents returning immediately to give the cluster some breathing
room before the admin can do other commands. Keep the write lock
as well to prevent other clients from attempting this as well.
The old way of doing this was a little cumbersome, with an upper YAML
tree split between "devices" (name and MTU) and addresses. This commit
unifies these under the root "networking" section to make this section
clearer.
MTUs were hardcoded at 9000, which breaks if the underlying interface
or network switch does not support jumbo frames, a possible deployment
limitation. This has non-obvious consequences due to MTU mismatches
for certain services (Ceph, Zookeeper, etc.).
This commit adds support for configurable MTUs for each interface,
set in pvcd.yaml. The example has been updated to reflect this, with
a default of 1500 (the Ethernet standard).
This commit also adds autoconfiguration of the VNI device MTU based
on the `vni_mtu` value, the same for bridge networks and minus 50
(rather than 200 from the hardcoded value, based on the following
resource [1]) for VXLAN networks.
[1] http://ipengineer.net/2014/06/vxlan-mtu-vs-ip-mtu-consideration/
Showing the static, total number of CPUs was pointless. Instead,
show the number of allocated vCPUs. To preserve space, no longer
show the host CPU count in the list.
Use RemainAfterExit to avoid pvc-flush from auto-stopping immediately.
Use PartOf to tie services to the target itself.
Use --wait on flush to avoid daemon stopping before flush is complete.
Add a systemd service to manage node flush/unflush, useful during
system startup and shutdown to avoid requiring administrator
intervention for this to occur. This is optional and the service is
not enabled by default, and the postinst script informs the
administrator of this.
Also adds a systemd target to collect the two service units together
and provide an easy way to flush+shutdown or startup+unflush the
entire PVC system.
Closes#28
1 second was just slightly too little time to wait and packets would
occasionally be lost on primary switchover. Increase this to 2
seconds to provide more time for arping to run on the new primary.
1. Remove a number of time.sleep commands which don't really seem
necessary any longer and which significantly increased the startup
time while parsing the VM list.
2. Handle some variable sets during initialization of the object,
rather than waiting for a management command, enabling...
3. Know when a state change, and the corresponding Libvirt lookup,
is unnecessary due to the target node not matching the current node.
This also removes a number of unremovable errors from Libvirt on the
console which were annoying.
This reduces the total time taken by the VM startup segment (lines
760-762 of Daemon.py) from 17.117s down to 0.976s for 82 VMs.