Commit Graph

193 Commits

Author SHA1 Message Date
Joshua Boniface cd1db3d587 Ensure node name is part of confing 2021-07-18 16:38:58 -04:00
Joshua Boniface 2e9f6ac201 Bump version to 0.9.25 2021-07-11 23:19:09 -04:00
Joshua Boniface f09849bedf Don't overwrite shutdown state on termination
Just a minor quibble and not really impactful.
2021-07-11 23:18:14 -04:00
Joshua Boniface c76149141f Only log ZK connections when persistent
Prevents spam in the API logs.
2021-07-10 23:35:49 -04:00
Joshua Boniface f00c4d07f4 Add date output to keepalive
Helps track when there is a log follow in "-o cat" mode.
2021-07-10 23:24:59 -04:00
Joshua Boniface 20b66c10e1 Move two more commands to Rados library 2021-07-10 17:28:42 -04:00
Joshua Boniface cfeba50b17 Revert "Return to all command-based Ceph gathering"
This reverts commit 65d14ccd92.

This was actually a bad idea. For inexplicable reasons, running these
Ceph commands manually (not even via Python, but in a normal shell)
takes 7 * two orders of magnitude longer than running them with the
Rados module, so long in fact that some basic commands like "ceph
health" would sometimes take longer than the 1 second timeout to
complete. The Rados commands would however take about 1ms instead.

Despite the occasional issues when monitors drop out, the Rados module
is clearly far superior to the shell commands for any moderately-loaded
Ceph cluster. We can look into solving timeouts another way (perhaps
with Processes instead of Threads) at a later time.

Rados module "ceph health":
    b'{"checks":{},"status":"HEALTH_OK"}'
    0.001204 (s)
    b'{"checks":{},"status":"HEALTH_OK"}'
    0.001258 (s)
Command "ceph health":
    joshua@hv1.c.bonilan.net ~ $ time ceph health >/dev/null
    real    0m0.772s
    user    0m0.707s
    sys     0m0.046s
    joshua@hv1.c.bonilan.net ~ $ time ceph health >/dev/null
    real    0m0.796s
    user    0m0.728s
    sys     0m0.054s
2021-07-10 03:47:45 -04:00
Joshua Boniface 551bae2518 Bump version to 0.9.24 2021-07-09 15:58:36 -04:00
Joshua Boniface 2b5dc286ab Correct failure to get ceph_health data 2021-07-09 13:10:28 -04:00
Joshua Boniface 330cf14638 Remove return statements in keepalive collectors
These seem to bork the keepalive timer process, so just remove them and
let it continue to press on.
2021-07-09 13:04:17 -04:00
Joshua Boniface 65d14ccd92 Return to all command-based Ceph gathering
Using the Rados module was very problematic, specifically because it had
no sensible timeout parameters and thus would hang for many seconds.
This has poor implications since it blocks further keepalives.

Instead, remove the Rados usage entirely and go back completely to using
manual OS commands to gather this information. While this may cause PID
exhaustion more quickly it's worthwhile to avoid failure scenarios when
Ceph stats time out.

Closes #137
2021-07-06 11:30:45 -04:00
Joshua Boniface 7082982a33 Bump version to 0.9.23 2021-07-05 23:40:32 -04:00
Joshua Boniface 5b6ef71909 Ensure daemon mode is updated on startup
Fixes the side effect of the previous bug during deploys of 0.9.22.
2021-07-05 23:39:23 -04:00
Joshua Boniface 37cd278bc2 Bump version to 0.9.22 2021-07-05 14:18:51 -04:00
Joshua Boniface a69105569f Add node PVC version data to Node information
Allows API client to see the currently-active version of the node
daemon.
2021-07-05 09:57:38 -04:00
Joshua Boniface f12de6727d Adjust logo slightly and add debug state 2021-07-02 02:32:08 -04:00
Joshua Boniface e94f5354e6 Update startup messages with new ASCII logo 2021-07-02 02:21:30 -04:00
Joshua Boniface c51023ba81 Add profiler to keepalive function 2021-07-02 01:55:15 -04:00
Joshua Boniface 39e82ee426 Cast base schema version to int
Or all our comparisons will fail later and nodes can't start.
2021-06-30 09:40:33 -04:00
Joshua Boniface fe0a1d582a Bump version to 0.9.21 2021-06-29 19:21:31 -04:00
Joshua Boniface e623909a43 Store PHY MAC for VFs and restore after free 2021-06-22 00:56:47 -04:00
Joshua Boniface eeb83da97d Add support for SR-IOV NICs to VMs 2021-06-21 23:18:22 -04:00
Joshua Boniface 64d1a37b3c Add PCIe device paths to SR-IOV VF information
This will be used when adding VM network interfaces of type hostdev.
2021-06-21 21:08:46 -04:00
Joshua Boniface 13cc0f986f Implement SR-IOV VF config set
Also fixes some random bugs, adds proper interface sorting, and assorted
tweaks.
2021-06-21 18:40:11 -04:00
Joshua Boniface ca11dbf491 Sort the list of VFs for easier parsing 2021-06-21 01:40:05 -04:00
Joshua Boniface e8bd1bf2c4 Ensure used/used_by are set on creation 2021-06-21 01:25:38 -04:00
Joshua Boniface 57b041dc62 Ensure default for vLAN and QOS is 0 not empty 2021-06-17 01:54:37 -04:00
Joshua Boniface 5607a6bb62 Avoid overwriting VF data
Ensures that the configuration of a VF is not overwritten in Zookeeper
on a node restart. The SRIOVVFInstance handlers were modified to start
with None values, so that the DataWatch statements will always trigger
updates to the live system interfaces on daemon startup, thus ensuring
that the config stored in Zookeeper is applied to the system on startup
(mostly relevant after a cold boot or if the API changes them during a
daemon restart).
2021-06-17 01:45:22 -04:00
Joshua Boniface 8f1af2a642 Ignore hostdev interfaces in VM net stat gathering
Prevents errors if a SR-IOV hostdev interface is configured until this
is more defined.
2021-06-17 01:33:11 -04:00
Joshua Boniface e7b6a3eac1 Implement SR-IOV PF and VF instances
Adds support for the node daemon managing SR-IOV PF and VF instances.

PFs are added to Zookeeper automatically based on the config at startup
during network configuration, and are otherwise completely static. PFs
are automatically removed from Zookeeper, along with all coresponding
VFs, should the PF phy device be removed from the configuration.

VFs are configured based on the (autocreated) VFs of each PF device,
added to Zookeeper, and then a new class instance, SRIOVVFInstance, is
used to watch them for configuration changes. This will enable the
runtime management of VF settings by the API. The set of keys ensures
that both configuration and details of the NIC can be tracked.

Most keys are self-explanatory, especially for PFs and the basic keys
for VFs. The configuration tree is also self-explanatory, being based
entirely on the options available in the `ip link set {dev} vf` command.

Two additional keys are also present: `used` and `used_by`, which will
be able to track the (boolean) state of usage, as well as the VM that
uses a given VIF. Since the VM side implementation will support both
macvtap and direct "hostdev" assignments, this will ensure that this
state can be tracked on both the VF and the VM side.
2021-06-17 01:33:03 -04:00
Joshua Boniface 0ad6d55dff Add initial SR-IOV support to node daemon
Adds configuration values for enabled flag and SR-IOV devices to the
configuration and sets up the initial SR-IOV configuration on daemon
startup (inserting the module, configuring the VF count, etc.).
2021-06-15 22:56:09 -04:00
Joshua Boniface 953e46055a Fix issue with loading None version schema 2021-06-14 21:09:55 -04:00
Joshua Boniface d2bcfe5cf7 Bump version to 0.9.20 2021-06-14 18:06:27 -04:00
Joshua Boniface 0a9c0c1ccb Use a nicer reload method on hot schema update
Instead of exiting and trusting systemd to restart us, instead leverage
the os.execv() call to reload the process in the current PID context.

Also improves the log messages so it's very clear what's going on.
2021-06-14 17:10:21 -04:00
Joshua Boniface e34a7d4d2a Handle hot reloads properly
A hot reload isn't possible due to DataWatch and ChildrenWatch
constructs, so we instead need to terminate the daemon to "apply" the
schema update. Thus we use exit code 150 (Application defined in LSB)
and reorder some of the elements of the schema validation to ensure
things happen in the right order.
2021-06-14 12:52:43 -04:00
Joshua Boniface b694945010 Fix incorrect name bug 2021-06-10 01:11:14 -04:00
Joshua Boniface f913f42a6d Replace schema paths with updated zkhandler 2021-06-09 20:29:42 -04:00
Joshua Boniface e475552391 Fix some bugs with hot reload 2021-06-09 00:03:26 -04:00
Joshua Boniface 5540bdc86b Add automatic schema upgrade to nodes
Performs an automatic schema upgrade when all nodes are updated to the
latest version.

Addresses #129
2021-06-08 23:35:39 -04:00
Joshua Boniface 3c102b3769 Add per-node schema tracking
This will allow nodes to start with their own schema versions, and then
be updated simultaneously by the API.

References #129
2021-06-08 23:35:39 -04:00
Joshua Boniface a4aaf89681 Add ZKSchema loading and validation to Daemon
Also removes some previous hack migrations from pre-0.9.19.

Addresses #129
2021-06-08 23:35:39 -04:00
Joshua Boniface cf96bb009f Bump version to 0.9.19 2021-06-06 01:47:41 -04:00
Joshua Boniface 7dea5d2fac Move logger to common, fix buffering 2021-06-01 18:50:26 -04:00
Joshua Boniface 9764090d6d Merge node common with daemon common 2021-06-01 12:22:11 -04:00
Joshua Boniface 12ac3686de Convert missed elements to new zkhandler 2021-06-01 11:57:21 -04:00
Joshua Boniface 1c9a7a6479 Convert VXNetworkInstance to new zkhandler 2021-06-01 11:49:39 -04:00
Joshua Boniface 790098f181 Convert VMInstance to new zkhandler 2021-06-01 11:46:27 -04:00
Joshua Boniface 8a4a41e092 Convert NodeInstance to new zkhandler 2021-06-01 11:27:35 -04:00
Joshua Boniface a0b9087167 Set Daemon migration selector in zookeeper 2021-06-01 10:52:41 -04:00
Joshua Boniface 33a54cf7f2 Move configuration keys to /config tree 2021-06-01 10:48:55 -04:00
Joshua Boniface d6a8cf9780 Convert MetadataAPIInstance to new zkhandler 2021-05-31 19:55:09 -04:00
Joshua Boniface abd619a3c1 Convert DNSAggregatorInstance to new zkhandler 2021-05-31 19:55:01 -04:00
Joshua Boniface ef5fe78125 Convert CepnInstance to new zkhandler 2021-05-31 19:51:27 -04:00
Joshua Boniface f6d0e89568 Properly add absent node type 2021-05-31 19:26:27 -04:00
Joshua Boniface ede3e88cd7 Modify node daemon root to use updated zkhandler 2021-05-31 03:14:09 -04:00
Joshua Boniface 0c75a127b2 Bump version to 0.9.18 2021-05-23 17:23:10 -04:00
Joshua Boniface 9de14c46fb Bump version to 0.9.17 2021-05-19 17:06:29 -04:00
Joshua Boniface fe15bdb854 Bump version to 0.9.16 2021-05-10 01:13:21 -04:00
Joshua Boniface 669338c22b Bump version to 0.9.15 2021-04-08 13:37:47 -04:00
Joshua Boniface c4ac75b973 Bump version to 0.9.14 2021-03-30 10:27:37 -04:00
Joshua Boniface 0bf276fd51 Update copyright year in headers 2021-03-25 17:01:55 -04:00
Joshua Boniface f4ec161aa2 Update file copyright header.
Remove the option to select a later version of the GPL.
2021-03-25 16:58:02 -04:00
Joshua Boniface 0ccfc41398 Bump version to 0.9.13 2021-02-17 11:37:59 -05:00
Joshua Boniface 9100c63e99 Add stored_bytes to pool stats information 2021-02-09 01:46:01 -05:00
Joshua Boniface aba567d6c9 Add nice startup banners to both daemons
Add nicer easy-to-find (yay ASCII art) banners for the startup printouts
of both the node and API daemons. Also adds the safe loader to pvcnoded
to prevent hassle messages and a version string in the API daemon file.
2021-02-08 02:51:43 -05:00
Joshua Boniface 0db8fd9da6 Bump version to 0.9.12 2021-01-28 16:29:58 -05:00
Joshua Boniface 9fbe35fd24 Bump version to 0.9.11 2021-01-05 15:58:26 -05:00
Joshua Boniface a24724d9f0 Use external ceph cmd for ceph df 2020-12-26 14:04:21 -05:00
Joshua Boniface 518d699c15 Bump version to 0.9.10 2020-12-15 10:45:15 -05:00
Joshua Boniface 7c99a7bda7 Safely reset RBD locks on failed VMs
Should correct issues on cold start as well as if a VM crashes
uncleanly, which would prevent the VM from starting due to stale RBD
locks.

This implementation has four parts:
  1. Update how IP addresses are handled, specifically by replacing all
  previous instances of "vni_ipaddr" with "vni_floatingipaddr", and then
  adding the "vni_ipaddr" with the real data for this node's IPs. Also
  include the storage IPs in this where they weren't before, so each
  this_node actually has the local IPs plus floating IPs. This enables
  the next two steps.
  2. Modify flush_locks to take this_node as an argument, and update the
  run_command function to only operate against this node, rather than on
  the primary coordinator.
  3. Have the flush_locks check each lock against the current node, to
  verify that the lock is actually held by the current node. This is the
  only way to do this safely. During fencing, we override this by not
  passing a this_node which bypasses this check.
  4. Have the VM start do the check for VM failure/startup and execute a
  flush_locks before actually starting the VM.
2020-12-14 15:53:18 -05:00
Joshua Boniface 89c7e225a0 Move OSD stats uploading to primary only
Instead of each node uploading its own OSD stats, which would not work
if the PVC daemon wasn't running, instead have the primary upload stats
for all OSDs in the cluster.
2020-12-09 02:46:09 -05:00
Joshua Boniface b36ec43a2d Bump version to 0.9.9 2020-12-09 02:20:20 -05:00
Joshua Boniface ce5ee11841 Bump version to 0.9.8 2020-11-24 12:26:57 -05:00
Joshua Boniface d4a28d7a58 Bump version to 0.9.7 2020-11-19 10:48:28 -05:00
Joshua Boniface e69eb93cb3 Bump version to 0.9.6 2020-11-17 13:01:54 -05:00
Joshua Boniface a4e5323e81 Bump version to 0.9.5 2020-11-17 12:34:04 -05:00
Joshua Boniface 9053edacd8 Bump version to 0.9.4 2020-11-10 15:33:50 -05:00
Joshua Boniface baac8f24fd Bump version to 0.9.3 2020-11-09 10:28:15 -05:00
Joshua Boniface 11702f4bc8 Bump version to 0.9.2 2020-11-08 02:03:29 -05:00
Joshua Boniface 6f66b77a00 Lint: E121/E126 continuation line under/over-indented for hanging indent 2020-11-07 15:06:21 -05:00
Joshua Boniface 260b39ebf2 Lint: E302 expected 2 blank lines, found X 2020-11-07 14:45:24 -05:00
Joshua Boniface c3dfe2e381 Lint: F821 undefined name 'myshorthostname' 2020-11-07 13:31:19 -05:00
Joshua Boniface 961ebb4c01 Lint: E305 expected 2 blank lines after class or function definition, found X 2020-11-07 13:17:49 -05:00
Joshua Boniface e553c5d42a Lint: E122 continuation line missing indentation or outdented 2020-11-07 13:12:26 -05:00
Joshua Boniface 7932be3948 Lint: E261 at least two spaces before inline comment 2020-11-07 13:11:03 -05:00
Joshua Boniface d2490419c5 Lint: E202 whitespace before ']' 2020-11-07 13:02:54 -05:00
Joshua Boniface d2e5ede399 Lint: E202 whitespace before ')' 2020-11-07 12:58:54 -05:00
Joshua Boniface 3f242cd437 Lint: E202 whitespace before '}' 2020-11-07 12:57:42 -05:00
Joshua Boniface b7daa8e1f6 E201 whitespace after '[' 2020-11-07 12:39:59 -05:00
Joshua Boniface c88965e898 Lint: E201 whitespace after '(' 2020-11-07 12:39:27 -05:00
Joshua Boniface e333f2b935 Lint: E201 whitespace after '{' 2020-11-07 12:38:31 -05:00
Joshua Boniface 8c623023d5 Lint: F811 redefinition of unused '<function>' 2020-11-07 12:14:29 -05:00
Joshua Boniface 2eef6a1c21 Lint: E265 block comment should start with '# ' 2020-11-06 21:32:17 -05:00
Joshua Boniface 5da314902f Lint: F841 local variable '<variable>' is assigned to but never used 2020-11-06 21:13:13 -05:00
Joshua Boniface 98a573bbc7 Lint: E402 module level import not at top of file 2020-11-06 20:40:32 -05:00
Joshua Boniface aecb845d6a Lint: E713 test for membership should be 'not in' 2020-11-06 20:37:52 -05:00
Joshua Boniface 57c51d3234 Lint: E711 comparison to None should be 'if cond is not None:' 2020-11-06 19:37:13 -05:00
Joshua Boniface ce01b41d81 Lint: E711 comparison to None should be 'if cond is None:' 2020-11-06 19:36:36 -05:00
Joshua Boniface ebf254f62d Lint: W293 blank line contains whitespace 2020-11-06 19:11:07 -05:00
Joshua Boniface 63f4f9aed7 Lint: E722 do not use bare 'except' 2020-11-06 18:55:10 -05:00