Commit Graph

97 Commits

Author SHA1 Message Date
Joshua Boniface 3c742a827b Initial implementation of monitoring plugin system 2023-02-13 12:06:26 -05:00
Joshua Boniface 726d0a562b Update copyright header year 2022-10-06 11:55:27 -04:00
Joshua Boniface 92e2ff7449 Fix bug with space-containing detect strings 2022-07-06 15:58:57 -04:00
Joshua Boniface 7a40c7a55b Add support for replacing/refreshing OSDs
Adds commands to both replace an OSD disk, and refresh (reimport) an
existing OSD disk on a new node. This handles the cases where an OSD
disk should be replaced (either due to upgrades or failures) or where a
node is rebuilt in-place and an existing OSD must be re-imported to it.

This should avoid the need to do a full remove/add sequence for either
case.

Also cleans up some aspects of OSD removal that are identical between
methods (e.g. using safe-to-destroy and sleeping after stopping) and
fixes a bug if an OSD does not truly exist when the daemon starts up.
2022-05-06 15:32:06 -04:00
Joshua Boniface 3801fcc07b Fix bug with initial JSON for stats 2022-05-02 13:28:19 -04:00
Joshua Boniface c741900baf Refactor OSD removal to use new ZK data
With the OSD LVM information stored in Zookeeper, we can use this to
determine the actual block device to zap rather than relying on runtime
determination and guestimation.
2022-05-02 12:52:22 -04:00
Joshua Boniface 464f0e0356 Store additional OSD information in ZK
Ensures that information like the FSIDs and the OSD LVM volume are
stored in Zookeeper at creation time and updated at daemon start time
(to ensure the data is populated at least once, or if the /dev/sdX
path changes).

This will allow safer operation of OSD removals and the potential
implementation of re-activation after node replacements.
2022-05-02 12:11:39 -04:00
Joshua Boniface cea8832f90 Ensure initial OSD stats is populated
Values are all invalid but this ensures the client won't error out when
trying to show an OSD that has never checked in yet.
2022-04-29 16:50:30 -04:00
Joshua Boniface d6ca74376a Fix bugs with forced removal 2022-04-29 14:03:07 -04:00
Joshua Boniface 4d698be34b Add OSD removal force option
Ensures a removal can continue even in situations where some step(s)
might fail, for instance removing an obsolete OSD from a replaced node.
2022-04-29 11:16:33 -04:00
Joshua Boniface 67131de4f6 Fix bug when removing OSDs
Ensure the OSD is down as well as out or purge might fail.
2021-12-28 03:05:34 -05:00
Joshua Boniface abc23ebb18 Handle detect strings as arguments for blockdevs
Allows specifying blockdevs in the OSD and OSD-DB addition commands as
detect strings rather than actual block device paths. This provides
greater flexibility for automation with pvcbootstrapd (which originates
the concept of detect strings) and in general usage as well.
2021-12-28 02:53:02 -05:00
Joshua Boniface 78faa90139 Reformat recent changes with Black 2021-11-06 03:27:07 -04:00
Joshua Boniface 66bfad3109 Fix linting errors F522/F523 unused args 2021-11-06 03:24:50 -04:00
Joshua Boniface c41664d2da Reformat code with Black code formatter
Unify the code style along PEP and Black principles using the tool.
2021-11-06 03:02:43 -04:00
Joshua Boniface dfebb2d3e5 Also validate on failures 2021-10-12 17:11:03 -04:00
Joshua Boniface b8204d89ac Go back to passing if exception
Validation already happened and the set happens again later.
2021-10-12 14:21:52 -04:00
Joshua Boniface 2d9fb9688d Validate network MTU after initial read 2021-10-12 10:53:17 -04:00
Joshua Boniface 3122d73bf5 Avoid duplicate runs of MTU set
It wasn't the validator duplicating, but the update duplicating, so
avoid that happening properly this time.
2021-10-09 19:21:47 -04:00
Joshua Boniface 7ed8ef179c Revert "Avoid duplicate runs of MTU validator"
This reverts commit 56021c443a.
2021-10-09 19:11:42 -04:00
Joshua Boniface caead02b2a Set all log messages to information state
None of these were "success" messages and thus shouldn't have been ok
state.
2021-10-09 19:09:38 -04:00
Joshua Boniface 87bc5f93e6 Avoid duplicate runs of MTU validator 2021-10-09 19:07:41 -04:00
Joshua Boniface 203893559e Use correct isinstance instead of type 2021-10-09 19:03:31 -04:00
Joshua Boniface 2c51bb0705 Move MTU validation to function
Prevents code duplication and ensures validation runs when an MTU is
updated, not just on network creation.
2021-10-09 19:01:45 -04:00
Joshua Boniface 46d3daf686 Add logger message when setting MTU 2021-10-09 18:56:18 -04:00
Joshua Boniface e9d05aa24e Ensure vx_mtu is always an int() 2021-10-09 18:52:50 -04:00
Joshua Boniface 6ce28c43af Add MTU value checking and log messages
Ensures that if a specified MTU is more than the maximum it is set to
the maximum instead, and adds warning messages for both situations.
2021-10-09 18:48:56 -04:00
Joshua Boniface c45f8f5bd5 Have VXNetworkInstance set MTU if unset
Makes this explicit in Zookeeper if a network is unset, post-migration
(schema version 6).

Addresses #144
2021-10-09 17:52:57 -04:00
Joshua Boniface 3690a2c1e0 Fix migration bugs and invalid vx_mtu
Addresses #144
2021-10-09 17:35:10 -04:00
Joshua Boniface 50d8aa0586 Add handlers for client network MTUs
Refactors some of the code in VXNetworkInterface to handle MTUs in a
more streamlined fashion. Also fixes a bug whereby bridge client
networks were being explicitly given the cluster dev MTU which might not
be correct. Now adds support for this option explicitly in the configs,
and defaults to 1500 for safety (the standard Ethernet MTU).

Addresses #144
2021-10-09 17:02:27 -04:00
Joshua Boniface 142c999ce8 Re-add success log output during migration 2021-09-27 11:50:55 -04:00
Joshua Boniface 55221b3d97 Simplify VM migration down to 3 steps
Remove two superfluous synchronization steps which are not needed here,
since the exclusive lock handles that situation anyways.

Still does not fix the weird flush->unflush lock timeout bug, but is
better worked-around now due to the cancelling of the other wait freeing
this up and continuing.
2021-09-27 00:03:20 -04:00
Joshua Boniface 0d72798814 Work around synchronization lock issues
Make the block on stage C only wait for 900 seconds (15 minutes) to
prevent indefinite blocking.

The issue comes if a VM is being received, and the current unflush is
cancelled for a flush. When this happens, this lock acquisition seems to
block for no obvious reason, and no other changes seem to affect it.
This is certainly some sort of locking bug within Kazoo but I can't
diagnose it as-is. Leave a TODO to look into this again in the future.
2021-09-26 23:26:21 -04:00
Joshua Boniface 3638efc77e Improve log messages during VM migration 2021-09-26 23:15:38 -04:00
Joshua Boniface c2c888d684 Use event to non-block wait and fix inf wait 2021-09-26 22:55:39 -04:00
Joshua Boniface febef2e406 Track status of VM state thread 2021-09-26 22:55:21 -04:00
Joshua Boniface 2a4f38e933 Simplify locking process for VM migration
Rather than using a cumbersome and overly complex ping-pong of read and
write locks, instead move to a much simpler process using exclusive
locks.

Describing the process in ASCII or narrative is cumbersome, but the
process ping-pongs via a set of exclusive locks and wait timers, so that
the two sides are able to synchronize via blocking the exclusive lock.
The end result is a much more streamlined migration (takes about half
the time all things considered) which should be less error-prone.
2021-09-26 22:08:07 -04:00
Joshua Boniface e23e2dd9bf Fix typo in log message 2021-09-26 03:35:30 -04:00
Joshua Boniface 0f02c5eaef Fix typo in sgdisk command options 2021-09-26 00:59:05 -04:00
Joshua Boniface 075abec5fe Use re.search instead of re.match
Required since we're not matching the start of the string.
2021-09-26 00:55:29 -04:00
Joshua Boniface 3a1cbf8d01 Raise basic exceptions in CephInstance
Avoids no exception to reraise errors on failures.
2021-09-26 00:50:10 -04:00
Joshua Boniface a438a4155a Fix OSD creation for partition paths and fix gdisk
The previous implementation did not work with /dev/nvme devices or any
/dev/disk/by-* devices due to some logical failures in the partition
naming scheme, so fix these, and be explicit about what is supported in
the PVC CLI command output.

The 'echo | gdisk' implementation of partition creation also did not
work due to limitations of subprocess.run; instead, use sgdisk which
allows these commands to be written out explicitly and is included in
the same package as gdisk.
2021-09-26 00:12:28 -04:00
Joshua Boniface 65df807b09 Add support for configurable OSD DB ratios
The default of 0.05 (5%) is likely ideal in the initial implementation,
but allow this to be set explicitly for maximum flexibility in
space-constrained or performance-critical use-cases.
2021-09-24 01:06:39 -04:00
Joshua Boniface adc8a5a3bc Add separate OSD DB device support
Adds in three parts:

1. Create an API endpoint to create OSD DB volume groups on a device.
Passed through to the node via the same command pipeline as
creating/removing OSDs, and creates a volume group with a fixed name
(osd-db).

2. Adds API support for specifying whether or not to use this DB volume
group when creating a new OSD via the "ext_db" flag. Naming and sizing
is fixed for simplicity and based on Ceph recommendations (5% of OSD
size). The Zookeeper schema tracks the block device to use during
removal.

3. Adds CLI support for the new and modified API endpoints, as well as
displaying the block device and DB block device in the OSD list.

While I debated supporting adding a DB device to an existing OSD, in
practice this ended up being a very complex operation involving stopping
the OSD and setting some options, so this is not supported; this can be
specified during OSD creation only.

Closes #142
2021-09-23 13:59:49 -04:00
Joshua Boniface e962743e51 Add VM device hot attach/detach support
Adds a new API endpoint to support hot attach/detach of devices, and the
corresponding client-side logic to use this endpoint when doing VM
network/storage add/remove actions.

The live attach is now the default behaviour for these types of
additions and removals, and can be disabled if needed.

Closes #141
2021-09-12 19:33:00 -04:00
Joshua Boniface fb46f5f9e9 Change default node object state to flushed 2021-08-29 03:34:08 -04:00
Joshua Boniface afb0359c20 Refactor pvcnoded to reduce Daemon.py size
This branch commit refactors the pvcnoded component to better adhere to
good programming practices. The previous Daemon.py was a massive file
which contained almost 2000 lines of direct, root-level code which was
directly imported. Not only was this poor practice, but this resulted
in a nigh-unmaintainable file which was hard even for me to understand.

This refactoring splits a large section of the code from Daemon.py into
separate small modules and functions in the `util/` directory. This will
hopefully make most of the functionality easy to find and modify without
having to dig through a single large file.

Further the existing subcomponents have been moved to the `objects/`
directory which clearly separates them.

Finally, the Daemon.py code has mostly been moved into a function,
`entrypoint()`, which is then called from the `pvcnoded.py` stub.

An additional item is that most format strings have been replaced by
f-strings to make use of the Python 3.6 features in Daemon.py and the
utility files.
2021-08-21 03:14:22 -04:00