Commit Graph

175 Commits

Author SHA1 Message Date
Joshua Boniface cd75413667 Increase initial lock timer
With the new library the reader seems to be a little too quick, so hold
the write lock for 1 second instead of 1/2 second to ensure it is
caught.
2021-06-01 17:00:11 -04:00
Joshua Boniface 9764090d6d Merge node common with daemon common 2021-06-01 12:22:11 -04:00
Joshua Boniface 12ac3686de Convert missed elements to new zkhandler 2021-06-01 11:57:21 -04:00
Joshua Boniface 5740d0f2d5 Remove obsolete zkhandler.py 2021-06-01 11:55:44 -04:00
Joshua Boniface 889f4cdf47 Convert common to new zkhandler 2021-06-01 11:55:32 -04:00
Joshua Boniface 8f66a8d00e Fix missed zkhandler conversion 2021-06-01 11:53:33 -04:00
Joshua Boniface 6beea0693c Convert fencing to new zkhandler 2021-06-01 11:53:21 -04:00
Joshua Boniface 1c9a7a6479 Convert VXNetworkInstance to new zkhandler 2021-06-01 11:49:39 -04:00
Joshua Boniface 790098f181 Convert VMInstance to new zkhandler 2021-06-01 11:46:27 -04:00
Joshua Boniface 8a4a41e092 Convert NodeInstance to new zkhandler 2021-06-01 11:27:35 -04:00
Joshua Boniface a48bf2d71e More gracefully handle none selectors
Allow selection of "none" as the node selector, and handle this by
always using the cluster default instead of writing it in.
2021-06-01 11:13:13 -04:00
Joshua Boniface a0b9087167 Set Daemon migration selector in zookeeper 2021-06-01 10:52:41 -04:00
Joshua Boniface 33a54cf7f2 Move configuration keys to /config tree 2021-06-01 10:48:55 -04:00
Joshua Boniface d6a8cf9780 Convert MetadataAPIInstance to new zkhandler 2021-05-31 19:55:09 -04:00
Joshua Boniface abd619a3c1 Convert DNSAggregatorInstance to new zkhandler 2021-05-31 19:55:01 -04:00
Joshua Boniface ef5fe78125 Convert CepnInstance to new zkhandler 2021-05-31 19:51:27 -04:00
Joshua Boniface f6d0e89568 Properly add absent node type 2021-05-31 19:26:27 -04:00
Joshua Boniface ede3e88cd7 Modify node daemon root to use updated zkhandler 2021-05-31 03:14:09 -04:00
Joshua Boniface 0c75a127b2 Bump version to 0.9.18 2021-05-23 17:23:10 -04:00
Joshua Boniface 9de14c46fb Bump version to 0.9.17 2021-05-19 17:06:29 -04:00
Joshua Boniface fe15bdb854 Bump version to 0.9.16 2021-05-10 01:13:21 -04:00
Joshua Boniface b851a6209c Catch all other exceptions in subprocess run
Found a rare glitch where the subprocess pipes would not engage, causing
a daemon crash. Catch these exceptions with a retcode of 255 instead of
bailing out.

Closes #124
2021-05-10 01:07:25 -04:00
Joshua Boniface 5ceb57e540 Handle emptying corrupted console log files
Libvirt will someones write junk out to console log files, which breaks
the log parser deque with a UnicodeDecodeError.

If this happens, clear the log and re-open the deque again for newer
updates.

Closes #123
2021-05-10 01:03:04 -04:00
Joshua Boniface 669338c22b Bump version to 0.9.15 2021-04-08 13:37:47 -04:00
Joshua Boniface c4ac75b973 Bump version to 0.9.14 2021-03-30 10:27:37 -04:00
Joshua Boniface 0bf276fd51 Update copyright year in headers 2021-03-25 17:01:55 -04:00
Joshua Boniface f4ec161aa2 Update file copyright header.
Remove the option to select a later version of the GPL.
2021-03-25 16:58:02 -04:00
Joshua Boniface 0ccfc41398 Bump version to 0.9.13 2021-02-17 11:37:59 -05:00
Joshua Boniface 9100c63e99 Add stored_bytes to pool stats information 2021-02-09 01:46:01 -05:00
Joshua Boniface aba567d6c9 Add nice startup banners to both daemons
Add nicer easy-to-find (yay ASCII art) banners for the startup printouts
of both the node and API daemons. Also adds the safe loader to pvcnoded
to prevent hassle messages and a version string in the API daemon file.
2021-02-08 02:51:43 -05:00
Joshua Boniface 0db8fd9da6 Bump version to 0.9.12 2021-01-28 16:29:58 -05:00
Joshua Boniface 9fbe35fd24 Bump version to 0.9.11 2021-01-05 15:58:26 -05:00
Joshua Boniface a24724d9f0 Use external ceph cmd for ceph df 2020-12-26 14:04:21 -05:00
Joshua Boniface 78c017d51d Remove erroneous extra colon in log output 2020-12-20 16:06:35 -05:00
Joshua Boniface 1b6613c280 Add live VNC information to domain output
Sets in the node daemon, returns via the API, and shows in the CLI,
information about the live VNC listen address and port for VNC-enabled
VMs.

Closes #115
2020-12-20 16:00:55 -05:00
Joshua Boniface d6ef722997 Fix bad log message 2020-12-15 10:51:52 -05:00
Joshua Boniface 518d699c15 Bump version to 0.9.10 2020-12-15 10:45:15 -05:00
Joshua Boniface ac3ef3d792 Revamp fencing order
Prevents unnecessarily excessive timeouts if IPMI connections time out;
before, would have to go through 3 timed out commands at ~20s each
before failure was registered; reduced to 1 if the first times out.
2020-12-15 02:48:25 -05:00
Joshua Boniface 3705daff43 Better handle failing RBD lock frees
If the VM is not in a stop state, failing to free the lock is now
considered a fatal error and will put the domain into fail state,
aborting the start. This is better than being unsafe or trying to start
a VM which will fail to boot due to read-only volumes.
2020-12-14 16:04:38 -05:00
Joshua Boniface 7c99a7bda7 Safely reset RBD locks on failed VMs
Should correct issues on cold start as well as if a VM crashes
uncleanly, which would prevent the VM from starting due to stale RBD
locks.

This implementation has four parts:
  1. Update how IP addresses are handled, specifically by replacing all
  previous instances of "vni_ipaddr" with "vni_floatingipaddr", and then
  adding the "vni_ipaddr" with the real data for this node's IPs. Also
  include the storage IPs in this where they weren't before, so each
  this_node actually has the local IPs plus floating IPs. This enables
  the next two steps.
  2. Modify flush_locks to take this_node as an argument, and update the
  run_command function to only operate against this node, rather than on
  the primary coordinator.
  3. Have the flush_locks check each lock against the current node, to
  verify that the lock is actually held by the current node. This is the
  only way to do this safely. During fencing, we override this by not
  passing a this_node which bypasses this check.
  4. Have the VM start do the check for VM failure/startup and execute a
  flush_locks before actually starting the VM.
2020-12-14 15:53:18 -05:00
Joshua Boniface 89c7e225a0 Move OSD stats uploading to primary only
Instead of each node uploading its own OSD stats, which would not work
if the PVC daemon wasn't running, instead have the primary upload stats
for all OSDs in the cluster.
2020-12-09 02:46:09 -05:00
Joshua Boniface b36ec43a2d Bump version to 0.9.9 2020-12-09 02:20:20 -05:00
Joshua Boniface ce5ee11841 Bump version to 0.9.8 2020-11-24 12:26:57 -05:00
Joshua Boniface d4a28d7a58 Bump version to 0.9.7 2020-11-19 10:48:28 -05:00
Joshua Boniface e69eb93cb3 Bump version to 0.9.6 2020-11-17 13:01:54 -05:00
Joshua Boniface 70dfcd434f Ensure inmigrate is cleared on failure 2020-11-17 12:57:37 -05:00
Joshua Boniface a4e5323e81 Bump version to 0.9.5 2020-11-17 12:34:04 -05:00
Joshua Boniface 9053edacd8 Bump version to 0.9.4 2020-11-10 15:33:50 -05:00
Joshua Boniface baac8f24fd Bump version to 0.9.3 2020-11-09 10:28:15 -05:00
Joshua Boniface 11702f4bc8 Bump version to 0.9.2 2020-11-08 02:03:29 -05:00