Commit Graph

3349 Commits

Author SHA1 Message Date
Joshua Boniface 4832245d9c Handle non-RBD disks and non-RBD errors better 2021-07-09 15:48:57 -04:00
Joshua Boniface 2138f2f59f Fail VM removal on disk removal failures
Prevents bad states where the VM is "removed" but some of its disks
remain due to e.g. stuck watchers.

Rearrange the sequence so it goes stop, delete disks, then delete VM,
and then return a failure if any of the disk(s) fail to remove, allowing
the task to be rerun after fixing the problem.
2021-07-09 15:39:06 -04:00
Joshua Boniface d1d355a96b Avoid errors if stats data is None 2021-07-09 13:13:54 -04:00
Joshua Boniface 2b5dc286ab Correct failure to get ceph_health data 2021-07-09 13:10:28 -04:00
Joshua Boniface c0c9327a7d Return an empty log if the value is None 2021-07-09 13:08:00 -04:00
Joshua Boniface 5ffabcfef5 Avoid failing if we can't get the future data 2021-07-09 13:05:37 -04:00
Joshua Boniface 330cf14638 Remove return statements in keepalive collectors
These seem to bork the keepalive timer process, so just remove them and
let it continue to press on.
2021-07-09 13:04:17 -04:00
Joshua Boniface 9d0eb20197 Mention UUID matching in vm list help 2021-07-09 11:51:20 -04:00
Joshua Boniface 3f5b7045a2 Allow raw listing of cluster names in CLI 2021-07-09 10:53:20 -04:00
Joshua Boniface 80fe96b24d Add some additional docstrings 2021-07-07 12:28:08 -04:00
Joshua Boniface 80f04ce8ee Remove connection renewal in state handler
Regenerating the ZK connection was fraught with issues, including
duplicate connections, strange failures to reconnect, and various other
wonkiness.

Instead let Kazoo handle states sensibly. Kazoo moves to SUSPENDED state
when it loses connectivity, and stays there indefinitely (based on
cursory tests). And Kazoo seems to always resume from this just fine on
its own. Thus all that hackery did nothing but complicate reconnection.

This therefore turns the listener into a purely informational function,
providing logs of when/why it failed, and we also add some additional
output messages during initial connection and final disconnection.
2021-07-07 11:55:12 -04:00
Joshua Boniface 65d14ccd92 Return to all command-based Ceph gathering
Using the Rados module was very problematic, specifically because it had
no sensible timeout parameters and thus would hang for many seconds.
This has poor implications since it blocks further keepalives.

Instead, remove the Rados usage entirely and go back completely to using
manual OS commands to gather this information. While this may cause PID
exhaustion more quickly it's worthwhile to avoid failure scenarios when
Ceph stats time out.

Closes #137
2021-07-06 11:30:45 -04:00
Joshua Boniface adc022f55d Add missing install of pvcapid-worker.sh 2021-07-06 09:40:42 -04:00
Joshua Boniface 7082982a33 Bump version to 0.9.23 2021-07-05 23:40:32 -04:00
Joshua Boniface 5b6ef71909 Ensure daemon mode is updated on startup
Fixes the side effect of the previous bug during deploys of 0.9.22.
2021-07-05 23:39:23 -04:00
Joshua Boniface a8c28786dd Better handle empty ipaths in schema
When trying to write to sub-item paths that don't yet exist, the
previous method would just blindly write to whatever the root key is,
which is never what we actually want.

Instead, check explicitly for a "base path" situation, and handle that.
Then, if we try to get a subpath that isn't valid, return None. Finally
in the various functions, if the path is None, just continue (or return
false/None) and (try to) chug along.
2021-07-05 23:35:03 -04:00
Joshua Boniface be7b0be8ed Fix typo in schema path name 2021-07-05 23:23:23 -04:00
Joshua Boniface c45804e8c1 Revert "Return none if a schema path is not found"
This reverts commit b1fcf6a4a5.
2021-07-05 23:16:39 -04:00
Joshua Boniface b1fcf6a4a5 Return none if a schema path is not found
This can cause overwriting of unintended keys, so should not be
happening. Will have to find the bugs this causes.
2021-07-05 17:15:55 -04:00
Joshua Boniface 47f39a1a2a Fix ordering issue in test-cluster script 2021-07-05 15:14:34 -04:00
Joshua Boniface 54f82a3ea0 Fix bug in VM network list with SR-IOV 2021-07-05 15:14:01 -04:00
Joshua Boniface 37cd278bc2 Bump version to 0.9.22 2021-07-05 14:18:51 -04:00
Joshua Boniface 47a522f8af Use manual zkhandler creation in Benchmark job
Like the other Celery job this does not work properly with the
ZKConnection decorator due to conflicting "self", so just connect
manually exactly like the provisioner task does.
2021-07-05 14:12:56 -04:00
Joshua Boniface 087c23859c Adjust layout of Provisioner lists output
Use the same header format as the others.
2021-07-05 14:06:22 -04:00
Joshua Boniface 6c21a52714 Adjust layout of Ceph/storage lists output
Use the same header format as node, VM, and network lists.
2021-07-05 12:57:18 -04:00
Joshua Boniface afde436cd0 Adjust layout of Network lists output
Use the same header format as node and VM lists.
2021-07-05 11:48:39 -04:00
Joshua Boniface 1fe71969ca Adjust layout of VM list output
Matches the new node list output format with the additional header line,
as well as revamps some other aspects:

    1. Adjusts the UUID to be under the name in the info output.
    2. Removes the UUID from the list output to save space, because this
       is generally not needed in day-to-day quick-list output.
    3. Renames the "Node" header to "Current" to better reflect what
       that column actually means and avoid conflicting with the parent
       header.
2021-07-05 10:52:48 -04:00
Joshua Boniface 2b04df22a6 Add PVC version to node information output
Also adjusts the layout of the node list output to avoid excessively
long lines. Adds another header line with categories and spacing dashes
for easier visual parsing.
2021-07-05 10:45:20 -04:00
Joshua Boniface a69105569f Add node PVC version data to Node information
Allows API client to see the currently-active version of the node
daemon.
2021-07-05 09:57:38 -04:00
Joshua Boniface 21a1a7da9e Fix bad schema reference
Not sure how this didn't cause an issue until now, but the wrong key
path was used and this was getting unexpected data with the newly-added
version string instead of the proper mode string.
2021-07-05 09:53:51 -04:00
Joshua Boniface e44f3d623e Remove unnecessary try/except blocks from VM reads
The zkhandler read() function takes care of ensuring there is a None
value returned if these fail, so these aren't required. Makes the code a
fair bit more readable here.
2021-07-02 12:01:58 -04:00
Joshua Boniface f0fd3d3f0e Make extra sure VMs terminate when told
When doing a stop_vm or terminate_vm, check again after 0.2 seconds
and try re-terminating if it's still running. Covers cases where a VM
doesn't stop if given the 'stop' state.
2021-07-02 11:40:34 -04:00
Joshua Boniface f12de6727d Adjust logo slightly and add debug state 2021-07-02 02:32:08 -04:00
Joshua Boniface e94f5354e6 Update startup messages with new ASCII logo 2021-07-02 02:21:30 -04:00
Joshua Boniface c51023ba81 Add profiler to keepalive function 2021-07-02 01:55:15 -04:00
Joshua Boniface 61465ef38f Add profiler to several other functions in API 2021-07-02 01:53:19 -04:00
Joshua Boniface 64c6b04352 Ensure all edited files are restored 2021-07-02 01:50:25 -04:00
Joshua Boniface 20542c3653 Add profiler to cluster status function 2021-07-01 17:35:29 -04:00
Joshua Boniface 00b503824e Set unstable version in API and CLI too 2021-07-01 17:35:11 -04:00
Joshua Boniface 43009486ae Move Ceph pool/volume list assembly to thread pool
Same reasons as the VM list, though less impactful.
2021-07-01 17:33:13 -04:00
Joshua Boniface 58789f1db4 Move VM list assembly to thread pool
This helps parallelize the numerous Zookeeper calls a little bit, at
least within the bounds of the GIL, to improve performance when getting
a large list of VMs. The max_workers value is capped at 32 to avoid
causing too many threads during concurrent executions, but still
provides a noticeable speedup (on the order of 0.2-0.4 seconds with 75
VMs, scaling up further as counts grow).
2021-07-01 17:32:47 -04:00
Joshua Boniface baf4c3fbc7 Add performance profiler function
Usable anywhere that the global daemon "config" parameter can be passed
in (e.g. pvcapid/helper.py, pvcnoded/Daemon.py, etc.). Stores results in
a subdirectory of the PVC logdir called "profiler" if this directory can
be created, or prints results.

The debug config parameter ensures that the profiler can be added to
functions and not run unless the server is explicitly in debug mode.
Might not be useful as I don't initially plan to add this to every
function (only when investigating performance problems), but this
flexibility allows that to change later.
2021-07-01 14:01:33 -04:00
Joshua Boniface e093efceb1 Add NoNodeError handlers in ZK locks
Instead of looping 5+ times acquiring an impossible lock on a
nonexistent key, just fail on a different error and return failure
immediately.

This is likely a major corner case that shouldn't happen, but better to
be safe than 500.
2021-07-01 01:17:38 -04:00
Joshua Boniface a080598781 Avoid superfluous ZK exists calls
These cause a major (2x) slowdown in read calls since Zookeeper
connections are expensive/slow. Instead, just try the thing and return
None if there's no key there.

Also wrap the children command in similar error handling since that did
not exist and could likely cause some bugs at some point.
2021-07-01 01:15:51 -04:00
Joshua Boniface 39e82ee426 Cast base schema version to int
Or all our comparisons will fail later and nodes can't start.
2021-06-30 09:40:33 -04:00
Joshua Boniface fe0a1d582a Bump version to 0.9.21 2021-06-29 19:21:31 -04:00
Joshua Boniface 64feabf7c0 Fix adds in bump-version 2021-06-29 19:20:13 -04:00
Joshua Boniface cc841898b4 Pad dimensions of logos slightly 2021-06-29 19:16:35 -04:00
Joshua Boniface de5599b800 Revert "Try dark image instead"
This reverts commit 87f963df4c.
2021-06-29 19:11:38 -04:00
Joshua Boniface 87f963df4c Try dark image instead 2021-06-29 19:09:39 -04:00