We already parse this information out anyways, so might as well add it
to the API output JSON. This can be leveraged by the Prometheus endpoint
as well to avoid duplicate listings.
This significantly simplifies cluster state handling by removing most of
the superfluous get_list() calls, replacing them with basic child reads
since most of them are just for a count anyways. The ones that require
states simplify this down to a child read plus direct reads for the
exact items required while leveraging the new read_many() function.
Adds a function, "read_many", which can take in multiple ZK keys and
return the values from all of them, using asyncio to avoid reading
sequentially.
Initial tests show a marked improvement in read performance of multiple
read()-heavy functions (e.g. "get_list()" functions) with this method.
Instead of using random hex characters from an md5sum, use a nice name
in all-caps similar to how Ceph does. This further helps prevent dupes
but also permits a changing health delta within a single event (which
would really only ever apply to plugin faults).
Since we already had a "details" field, simply move where it gets added
to the message later, in generate_fault, after the main message value
was used to generate the ID.
This ensures that certain faults e.g. Ceph status faults, will be
combined despite the added text in brackets, while still keeping them
mostly separate.
Also ensure the health text is updated each time to assist with this, as
this health text may now change independent of the fault ID.
Adjusts ordering and ensures that node health states are included in
faults if they are less than 50%.
Also adjusts fault ID generation and runs fault checks only coordinator
nodes to avoid too many runs.
Moves all tasks run by the Celery worker into a discrete package/module
for easier installation. Also adjusts several parameters throughout to
accomplish this.
Ensures that messages are fully read before each append. Adds more
Zookeeper hits, but ensures logs won't be overwritten by multiple
daemons.
Also don't use a set on the client side, to avoid "removing duplicate"
entries erroneously.
This is still needed due to the nature of the locks and freeing them on
startup, and to preserve lock=fail behaviour on VM startup.
Also fixes the fencing lock flush to directly use the client library
outside of Celery. I don't like this hack but it seems prudent until we
move fencing to the workers as well.
1. Simplify this by leveraging the existing remove_osd/add_osd
functions, since its task was functionally identical to those two in
sequential order.
2. Add support for split OSDs within the command (replacing all OSDs on
the block device(s) as required).
3. Add additional configurability and flexibility around the old device,
weight, and external DB LVs.
Allows creating multiple OSDs on a single (NVMe) block device,
leveraging the "ceph-volume lvm batch" command. Replaces the previous
method of creating OSDs.
Also adds a new ZK item for each OSD indicating if it is split or not.
This helps ensure an easier restore as the tar archive(s) can be sent
directly to the API via the normal process of image uploading, instead
of individual disks.
Converting into human results in imprecise values when specifying bytes
directly, which in turn breaks VMDK image uploads. Instead, just use the
raw bytes value when creating the volume instead of converting it back.
It didn't make any sense to me for mem(prov) to be the default selector,
since this has too many caveats versus mem(free). Switch to using
mem(free) as the default (i.e. "mem") and make memprov the alternative.
Otherwise the node entries could come back in an arbitrary order; since
this is an ordered list of dictionaries that might not be expected by
the API consumers, so ensure it's always sorted.
1. Add documentation on the node selector flags. In the API, reference
the daemon configuration manual which now includes details in this
section; in the CLI, provide the help in "pvc vm define" in detail and
then reference that command's help in the other commands that use this
field.
2. Ensure the naming is consistent in the CLI, using the flag name
"--node-selector" everywhere (was "--selector" for "pvc vm" commands and
"--node-selector" for "pvc provisioner" commands).
Adds commands to both replace an OSD disk, and refresh (reimport) an
existing OSD disk on a new node. This handles the cases where an OSD
disk should be replaced (either due to upgrades or failures) or where a
node is rebuilt in-place and an existing OSD must be re-imported to it.
This should avoid the need to do a full remove/add sequence for either
case.
Also cleans up some aspects of OSD removal that are identical between
methods (e.g. using safe-to-destroy and sleeping after stopping) and
fixes a bug if an OSD does not truly exist when the daemon starts up.
Ensures that information like the FSIDs and the OSD LVM volume are
stored in Zookeeper at creation time and updated at daemon start time
(to ensure the data is populated at least once, or if the /dev/sdX
path changes).
This will allow safer operation of OSD removals and the potential
implementation of re-activation after node replacements.
Allows an administrator to adjust the PG count of a given pool. This can
be used to increase the PGs (for example after adding more OSDs) or
decrease it (to remove OSDs, reduce CPU load, etc.).
Allows specifying a particular device class ("tier") for a given pool,
for instance SSD-only or NVMe-only. This is implemented with Crush
rules on the Ceph side, and via an additional new key in the pool
Zookeeper schema which is defaulted to "default".
Solves two problems:
1. How match fuzziness was used was very inconsistent; make them all the
same, i.e. "if is_fuzzy and limit, apply .* to both sides".
2. Use re.fullmatch instead of re.match to ensure exact matching of the
regex to the value. Without fuzziness, this would sometimes cause
inconsistent behavior, for instance if a limit was non-fuzzy "vm",
expecting to match the actual "vm", but also matching "vm1" too.
Instead of requiring the VM to already be stopped, instead allow disable
state changes to perform a shutdown first. Also add a force option which
will do a hard stop instead of a shutdown.
References #148
Refactors some of the code in VXNetworkInterface to handle MTUs in a
more streamlined fashion. Also fixes a bug whereby bridge client
networks were being explicitly given the cluster dev MTU which might not
be correct. Now adds support for this option explicitly in the configs,
and defaults to 1500 for safety (the standard Ethernet MTU).
Addresses #144
When using the "state", "node", or "tag" arguments to a VM list, add
support for a "negate" flag to look for all VMs *not in* the state,
node, or tag state.
The default of 0.05 (5%) is likely ideal in the initial implementation,
but allow this to be set explicitly for maximum flexibility in
space-constrained or performance-critical use-cases.
Adds in three parts:
1. Create an API endpoint to create OSD DB volume groups on a device.
Passed through to the node via the same command pipeline as
creating/removing OSDs, and creates a volume group with a fixed name
(osd-db).
2. Adds API support for specifying whether or not to use this DB volume
group when creating a new OSD via the "ext_db" flag. Naming and sizing
is fixed for simplicity and based on Ceph recommendations (5% of OSD
size). The Zookeeper schema tracks the block device to use during
removal.
3. Adds CLI support for the new and modified API endpoints, as well as
displaying the block device and DB block device in the OSD list.
While I debated supporting adding a DB device to an existing OSD, in
practice this ended up being a very complex operation involving stopping
the OSD and setting some options, so this is not supported; this can be
specified during OSD creation only.
Closes#142
Ensures that a VM won't:
(a) Have provisioned more RAM than there is available on a given node.
Due to memory overprovisioning, this is simply a "is the VM memory count
more than the node count", and doesn't factor in free or used memory on
a node, total cluster usage, etc. So if a node has 64GB total RAM, the
VM limit is 64GB. It is up to an administrator to ensure sanity *below*
that value.
(b) Have provisioned more vCPUs than there are CPU cores on the node,
minus 2 to account for hypervisor/storage processes. Will ensure there
is no severe CPU contention caused by a single VM having more vCPUs than
there are actual execution threads available.
Closes#139
Adds a new API endpoint to support hot attach/detach of devices, and the
corresponding client-side logic to use this endpoint when doing VM
network/storage add/remove actions.
The live attach is now the default behaviour for these types of
additions and removals, and can be disabled if needed.
Closes#141
This should be managed in ceph.conf with the `rbd default
features` configuration option instead, and thus can be tailored to the
underlying OS version.
If this isn't, the resize will be interpreted as a MB value and result
in an absurdly big volume instead. This is the same consistency
validation that occurs on add.
Convert from human to bytes, then to megabytes and always pass this to
the RBD command. This ensures consistency regardless of what is actually
passed by the user.