Commit Graph

645 Commits

Author SHA1 Message Date
Joshua Boniface 8d0f26ff7a Add additional kb_ values to OSD stats
Allows for easier parsing later to get e.g. % values and more details on
the used amounts.
2022-08-11 11:06:36 -04:00
Joshua Boniface 645b525ad7 Bump version to 0.9.51 2022-07-25 23:25:41 -04:00
Joshua Boniface ec559aec0d Remove pvc-flush service
This service caused more headaches than it was worth, so remove it.

The original goal was to cleanly flush nodes on shutdown and unflush
them on startup, but this is tightly controlled by Ansible playbooks at
this point, and this is something best left to the Administrator and
their particular situation anyways.
2022-07-25 23:21:34 -04:00
Joshua Boniface 932b3c55a3 Bump version to 0.9.50 2022-07-06 16:01:14 -04:00
Joshua Boniface 92e2ff7449 Fix bug with space-containing detect strings 2022-07-06 15:58:57 -04:00
Joshua Boniface f8cdcb30ba Add migration selector via free memory
Closes #152
2022-05-18 03:47:16 -04:00
Joshua Boniface 51ad2058ed Bump version to 0.9.49 2022-05-06 15:49:39 -04:00
Joshua Boniface 7a40c7a55b Add support for replacing/refreshing OSDs
Adds commands to both replace an OSD disk, and refresh (reimport) an
existing OSD disk on a new node. This handles the cases where an OSD
disk should be replaced (either due to upgrades or failures) or where a
node is rebuilt in-place and an existing OSD must be re-imported to it.

This should avoid the need to do a full remove/add sequence for either
case.

Also cleans up some aspects of OSD removal that are identical between
methods (e.g. using safe-to-destroy and sleeping after stopping) and
fixes a bug if an OSD does not truly exist when the daemon starts up.
2022-05-06 15:32:06 -04:00
Joshua Boniface 3801fcc07b Fix bug with initial JSON for stats 2022-05-02 13:28:19 -04:00
Joshua Boniface c741900baf Refactor OSD removal to use new ZK data
With the OSD LVM information stored in Zookeeper, we can use this to
determine the actual block device to zap rather than relying on runtime
determination and guestimation.
2022-05-02 12:52:22 -04:00
Joshua Boniface 464f0e0356 Store additional OSD information in ZK
Ensures that information like the FSIDs and the OSD LVM volume are
stored in Zookeeper at creation time and updated at daemon start time
(to ensure the data is populated at least once, or if the /dev/sdX
path changes).

This will allow safer operation of OSD removals and the potential
implementation of re-activation after node replacements.
2022-05-02 12:11:39 -04:00
Joshua Boniface cea8832f90 Ensure initial OSD stats is populated
Values are all invalid but this ensures the client won't error out when
trying to show an OSD that has never checked in yet.
2022-04-29 16:50:30 -04:00
Joshua Boniface 5807351405 Bump version to 0.9.48 2022-04-29 15:03:52 -04:00
Joshua Boniface d6ca74376a Fix bugs with forced removal 2022-04-29 14:03:07 -04:00
Joshua Boniface 4d698be34b Add OSD removal force option
Ensures a removal can continue even in situations where some step(s)
might fail, for instance removing an obsolete OSD from a replaced node.
2022-04-29 11:16:33 -04:00
Joshua Boniface ea709f573f Bump version to 0.9.47 2021-12-28 22:03:08 -05:00
Joshua Boniface 58d57d7037 Bump version to 0.9.46 2021-12-28 15:02:14 -05:00
Joshua Boniface 00d2c67c41 Allow single-node clusters to restart and timeout
Prevents a daemon from waiting forever to terminate if it is primary,
and avoids this entirely if there is only a single node in the cluster.
2021-12-28 03:06:03 -05:00
Joshua Boniface 67131de4f6 Fix bug when removing OSDs
Ensure the OSD is down as well as out or purge might fail.
2021-12-28 03:05:34 -05:00
Joshua Boniface abc23ebb18 Handle detect strings as arguments for blockdevs
Allows specifying blockdevs in the OSD and OSD-DB addition commands as
detect strings rather than actual block device paths. This provides
greater flexibility for automation with pvcbootstrapd (which originates
the concept of detect strings) and in general usage as well.
2021-12-28 02:53:02 -05:00
Joshua Boniface f164d898c1 Bump version to 0.9.45 2021-11-25 09:34:20 -05:00
Joshua Boniface a8899a1d66 Fix ordering of pvcnoded unit
We want to be after network.target and want network-online.target
2021-11-18 16:56:49 -05:00
Joshua Boniface 817dffcf30 Bump version to 0.9.44 2021-11-11 16:20:38 -05:00
Joshua Boniface eda2a57a73 Add Munin plugin for Ceph utilization 2021-11-08 15:21:09 -05:00
Joshua Boniface 6e9fcd38a3 Bump version to 0.9.43 2021-11-08 02:29:17 -05:00
Joshua Boniface 78faa90139 Reformat recent changes with Black 2021-11-06 03:27:07 -04:00
Joshua Boniface 23b1501f40 Fix linting error F541 f-string placeholders 2021-11-06 03:26:03 -04:00
Joshua Boniface 66bfad3109 Fix linting errors F522/F523 unused args 2021-11-06 03:24:50 -04:00
Joshua Boniface c41664d2da Reformat code with Black code formatter
Unify the code style along PEP and Black principles using the tool.
2021-11-06 03:02:43 -04:00
Joshua Boniface 2e7b9b28b3 Add some delay and additional tries to fencing 2021-10-27 16:24:17 -04:00
Joshua Boniface 55f397a347 Fix bad location of config sets 2021-10-12 17:23:04 -04:00
Joshua Boniface dfebb2d3e5 Also validate on failures 2021-10-12 17:11:03 -04:00
Joshua Boniface e88147db4a Bump version to 0.9.42 2021-10-12 15:25:42 -04:00
Joshua Boniface b8204d89ac Go back to passing if exception
Validation already happened and the set happens again later.
2021-10-12 14:21:52 -04:00
Joshua Boniface fe73dfbdc9 Use current live value for bridge_mtu
This will ensure that upgrading without the bridge_mtu config key set
will keep things as they are.
2021-10-12 12:24:03 -04:00
Joshua Boniface 8f906c1f81 Use power off in fence instead of reset
Use a power off (and then make the power on a requirement) during a node
fence. Removes some potential ambiguity in the power state, since we
will know for certain if it is off.
2021-10-12 11:04:27 -04:00
Joshua Boniface 2d9fb9688d Validate network MTU after initial read 2021-10-12 10:53:17 -04:00
Joshua Boniface f13cc04b89 Bump version to 0.9.41 2021-10-09 19:39:21 -04:00
Joshua Boniface 95e01f38d5 Adjust log type of object setup message 2021-10-09 19:23:12 -04:00
Joshua Boniface 3122d73bf5 Avoid duplicate runs of MTU set
It wasn't the validator duplicating, but the update duplicating, so
avoid that happening properly this time.
2021-10-09 19:21:47 -04:00
Joshua Boniface 7ed8ef179c Revert "Avoid duplicate runs of MTU validator"
This reverts commit 56021c443a.
2021-10-09 19:11:42 -04:00
Joshua Boniface caead02b2a Set all log messages to information state
None of these were "success" messages and thus shouldn't have been ok
state.
2021-10-09 19:09:38 -04:00
Joshua Boniface 87bc5f93e6 Avoid duplicate runs of MTU validator 2021-10-09 19:07:41 -04:00
Joshua Boniface 203893559e Use correct isinstance instead of type 2021-10-09 19:03:31 -04:00
Joshua Boniface 2c51bb0705 Move MTU validation to function
Prevents code duplication and ensures validation runs when an MTU is
updated, not just on network creation.
2021-10-09 19:01:45 -04:00
Joshua Boniface 46d3daf686 Add logger message when setting MTU 2021-10-09 18:56:18 -04:00
Joshua Boniface e9d05aa24e Ensure vx_mtu is always an int() 2021-10-09 18:52:50 -04:00
Joshua Boniface 6ce28c43af Add MTU value checking and log messages
Ensures that if a specified MTU is more than the maximum it is set to
the maximum instead, and adds warning messages for both situations.
2021-10-09 18:48:56 -04:00
Joshua Boniface c45f8f5bd5 Have VXNetworkInstance set MTU if unset
Makes this explicit in Zookeeper if a network is unset, post-migration
(schema version 6).

Addresses #144
2021-10-09 17:52:57 -04:00
Joshua Boniface 3690a2c1e0 Fix migration bugs and invalid vx_mtu
Addresses #144
2021-10-09 17:35:10 -04:00