Commit Graph

503 Commits

Author SHA1 Message Date
Joshua Boniface e23a65128a Remove del of logger item 2021-07-18 19:03:47 -04:00
Joshua Boniface 3a2478ee0c Cleanly terminate logger on cleanup 2021-07-18 18:57:44 -04:00
Joshua Boniface 323c7c41ae Implement node logging into Zookeeper
Adds the ability to send node daemon logs to Zookeeper to facilitate a
command like "pvc node log", similar to "pvc vm log". Each node stores
its logs in a separate tree under "/logs" which can then be combined or
queried. By default, set by config, only 2000 lines are kept.
2021-07-18 17:11:43 -04:00
Joshua Boniface cd1db3d587 Ensure node name is part of confing 2021-07-18 16:38:58 -04:00
Joshua Boniface 75fb60b1b4 Add VM list filtering by tag
Uses same method as state or node filtering, rather than altering how
the main LIMIT field works.
2021-07-14 00:59:20 -04:00
Joshua Boniface c6d552ae57 Rework success checks for IPMI fencing
Previously, if the node failed to restart, it was declared a "bad fence"
and no further action would be taken. However, there are some
situations, for instance critical hardware failures, where intelligent
systems will not attempt (or succeed at) starting up the node in such a
case, which would result in dead, known-offline nodes without recovery.

Tweak this behaviour somewhat. The main path of Reboot -> Check On ->
Success + fence-flush is retained, but some additional side-paths are
now defined:

1. We attempt to power "on" the chassis 1 second after the reboot, just
in case it is off and can be recovered. We then wait another 2 seconds
and check the power status (as we did before).

2. If the reboot succeeded, follow this series of choices:

    a. If the chassis is on, the fence succeeded.

    b. If the chassis is off, the fence "succeeded" as well.

    c. If the chassis is in some other state, the fence failed.

3. If the reboot failed, follow this series of choices:

    a. If the chassis is off, the fence itself failed, but we can treat
    it as "succeeded"" since the chassis is in a known-offline state.
    This is the most likely situation when there is a critical hardware
    failure, and the server's IPMI does not allow itself to start back
    up again.

    b. If the chassis is in any other state ("on" or unknown), the fence
    itself failed and we must treat this as a fence failure.

Overall, this should alleviate the aforementioned issue of a critical
failure rendering the node persistently "off" not triggering a
fence-flush and ensure fencing is more robust.
2021-07-13 17:54:41 -04:00
Joshua Boniface 2e9f6ac201 Bump version to 0.9.25 2021-07-11 23:19:09 -04:00
Joshua Boniface f09849bedf Don't overwrite shutdown state on termination
Just a minor quibble and not really impactful.
2021-07-11 23:18:14 -04:00
Joshua Boniface c76149141f Only log ZK connections when persistent
Prevents spam in the API logs.
2021-07-10 23:35:49 -04:00
Joshua Boniface f00c4d07f4 Add date output to keepalive
Helps track when there is a log follow in "-o cat" mode.
2021-07-10 23:24:59 -04:00
Joshua Boniface 20b66c10e1 Move two more commands to Rados library 2021-07-10 17:28:42 -04:00
Joshua Boniface cfeba50b17 Revert "Return to all command-based Ceph gathering"
This reverts commit 65d14ccd92.

This was actually a bad idea. For inexplicable reasons, running these
Ceph commands manually (not even via Python, but in a normal shell)
takes 7 * two orders of magnitude longer than running them with the
Rados module, so long in fact that some basic commands like "ceph
health" would sometimes take longer than the 1 second timeout to
complete. The Rados commands would however take about 1ms instead.

Despite the occasional issues when monitors drop out, the Rados module
is clearly far superior to the shell commands for any moderately-loaded
Ceph cluster. We can look into solving timeouts another way (perhaps
with Processes instead of Threads) at a later time.

Rados module "ceph health":
    b'{"checks":{},"status":"HEALTH_OK"}'
    0.001204 (s)
    b'{"checks":{},"status":"HEALTH_OK"}'
    0.001258 (s)
Command "ceph health":
    joshua@hv1.c.bonilan.net ~ $ time ceph health >/dev/null
    real    0m0.772s
    user    0m0.707s
    sys     0m0.046s
    joshua@hv1.c.bonilan.net ~ $ time ceph health >/dev/null
    real    0m0.796s
    user    0m0.728s
    sys     0m0.054s
2021-07-10 03:47:45 -04:00
Joshua Boniface 551bae2518 Bump version to 0.9.24 2021-07-09 15:58:36 -04:00
Joshua Boniface 2b5dc286ab Correct failure to get ceph_health data 2021-07-09 13:10:28 -04:00
Joshua Boniface 330cf14638 Remove return statements in keepalive collectors
These seem to bork the keepalive timer process, so just remove them and
let it continue to press on.
2021-07-09 13:04:17 -04:00
Joshua Boniface 65d14ccd92 Return to all command-based Ceph gathering
Using the Rados module was very problematic, specifically because it had
no sensible timeout parameters and thus would hang for many seconds.
This has poor implications since it blocks further keepalives.

Instead, remove the Rados usage entirely and go back completely to using
manual OS commands to gather this information. While this may cause PID
exhaustion more quickly it's worthwhile to avoid failure scenarios when
Ceph stats time out.

Closes #137
2021-07-06 11:30:45 -04:00
Joshua Boniface 7082982a33 Bump version to 0.9.23 2021-07-05 23:40:32 -04:00
Joshua Boniface 5b6ef71909 Ensure daemon mode is updated on startup
Fixes the side effect of the previous bug during deploys of 0.9.22.
2021-07-05 23:39:23 -04:00
Joshua Boniface be7b0be8ed Fix typo in schema path name 2021-07-05 23:23:23 -04:00
Joshua Boniface 37cd278bc2 Bump version to 0.9.22 2021-07-05 14:18:51 -04:00
Joshua Boniface a69105569f Add node PVC version data to Node information
Allows API client to see the currently-active version of the node
daemon.
2021-07-05 09:57:38 -04:00
Joshua Boniface 21a1a7da9e Fix bad schema reference
Not sure how this didn't cause an issue until now, but the wrong key
path was used and this was getting unexpected data with the newly-added
version string instead of the proper mode string.
2021-07-05 09:53:51 -04:00
Joshua Boniface f0fd3d3f0e Make extra sure VMs terminate when told
When doing a stop_vm or terminate_vm, check again after 0.2 seconds
and try re-terminating if it's still running. Covers cases where a VM
doesn't stop if given the 'stop' state.
2021-07-02 11:40:34 -04:00
Joshua Boniface f12de6727d Adjust logo slightly and add debug state 2021-07-02 02:32:08 -04:00
Joshua Boniface e94f5354e6 Update startup messages with new ASCII logo 2021-07-02 02:21:30 -04:00
Joshua Boniface c51023ba81 Add profiler to keepalive function 2021-07-02 01:55:15 -04:00
Joshua Boniface 39e82ee426 Cast base schema version to int
Or all our comparisons will fail later and nodes can't start.
2021-06-30 09:40:33 -04:00
Joshua Boniface fe0a1d582a Bump version to 0.9.21 2021-06-29 19:21:31 -04:00
Joshua Boniface 3490ecbb59 Remove explicit ZK address from Patronictl command 2021-06-22 03:31:06 -04:00
Joshua Boniface 2928d695c9 Ensure migration method is updated on state changes 2021-06-22 03:20:15 -04:00
Joshua Boniface 26dd24e3f5 Ensure MTU is set on VF when starting up 2021-06-22 02:26:14 -04:00
Joshua Boniface e623909a43 Store PHY MAC for VFs and restore after free 2021-06-22 00:56:47 -04:00
Joshua Boniface 60e1da09dd Don't try any shenannegans when updating NICs
Trying to do this on the VMInstance side had problems because we can't
differentiate the 3 types of migration there. So, just update this in
the API side and hope everything goes well.

This introduces an edge bug: if a VM is using a macvtap SR-IOV device,
and then tries to migrate, and the migrate is aborted, the NIC lists
will be inconsistent.

When I revamp the VMInstance in the future, I should be able to correct
this, but for now we'll have to live with that edgecase.
2021-06-22 00:00:50 -04:00
Joshua Boniface 7d42fba373 Ensure being in migrate doesn't abort shutdown 2021-06-21 23:28:53 -04:00
Joshua Boniface 24ce361a04 Ensure SR-IOV NIC states are updated on migration 2021-06-21 23:18:34 -04:00
Joshua Boniface eeb83da97d Add support for SR-IOV NICs to VMs 2021-06-21 23:18:22 -04:00
Joshua Boniface 64d1a37b3c Add PCIe device paths to SR-IOV VF information
This will be used when adding VM network interfaces of type hostdev.
2021-06-21 21:08:46 -04:00
Joshua Boniface 13cc0f986f Implement SR-IOV VF config set
Also fixes some random bugs, adds proper interface sorting, and assorted
tweaks.
2021-06-21 18:40:11 -04:00
Joshua Boniface ca11dbf491 Sort the list of VFs for easier parsing 2021-06-21 01:40:05 -04:00
Joshua Boniface e8bd1bf2c4 Ensure used/used_by are set on creation 2021-06-21 01:25:38 -04:00
Joshua Boniface bff6d71e18 Add logging to SRIOVVFInstance and fix bug 2021-06-17 02:02:41 -04:00
Joshua Boniface 57b041dc62 Ensure default for vLAN and QOS is 0 not empty 2021-06-17 01:54:37 -04:00
Joshua Boniface 5607a6bb62 Avoid overwriting VF data
Ensures that the configuration of a VF is not overwritten in Zookeeper
on a node restart. The SRIOVVFInstance handlers were modified to start
with None values, so that the DataWatch statements will always trigger
updates to the live system interfaces on daemon startup, thus ensuring
that the config stored in Zookeeper is applied to the system on startup
(mostly relevant after a cold boot or if the API changes them during a
daemon restart).
2021-06-17 01:45:22 -04:00
Joshua Boniface 8f1af2a642 Ignore hostdev interfaces in VM net stat gathering
Prevents errors if a SR-IOV hostdev interface is configured until this
is more defined.
2021-06-17 01:33:11 -04:00
Joshua Boniface e7b6a3eac1 Implement SR-IOV PF and VF instances
Adds support for the node daemon managing SR-IOV PF and VF instances.

PFs are added to Zookeeper automatically based on the config at startup
during network configuration, and are otherwise completely static. PFs
are automatically removed from Zookeeper, along with all coresponding
VFs, should the PF phy device be removed from the configuration.

VFs are configured based on the (autocreated) VFs of each PF device,
added to Zookeeper, and then a new class instance, SRIOVVFInstance, is
used to watch them for configuration changes. This will enable the
runtime management of VF settings by the API. The set of keys ensures
that both configuration and details of the NIC can be tracked.

Most keys are self-explanatory, especially for PFs and the basic keys
for VFs. The configuration tree is also self-explanatory, being based
entirely on the options available in the `ip link set {dev} vf` command.

Two additional keys are also present: `used` and `used_by`, which will
be able to track the (boolean) state of usage, as well as the VM that
uses a given VIF. Since the VM side implementation will support both
macvtap and direct "hostdev" assignments, this will ensure that this
state can be tracked on both the VF and the VM side.
2021-06-17 01:33:03 -04:00
Joshua Boniface 0ad6d55dff Add initial SR-IOV support to node daemon
Adds configuration values for enabled flag and SR-IOV devices to the
configuration and sets up the initial SR-IOV configuration on daemon
startup (inserting the module, configuring the VF count, etc.).
2021-06-15 22:56:09 -04:00
Joshua Boniface e4a65230a1 Just do the shutdown command itself 2021-06-15 02:32:14 -04:00
Joshua Boniface 284c581845 Ensure shutdown migrations actually time out
Without this a VM that fails to respond to a shutdown will just spin
forever, blocking state changes.
2021-06-15 00:23:15 -04:00
Joshua Boniface 953e46055a Fix issue with loading None version schema 2021-06-14 21:09:55 -04:00
Joshua Boniface d2bcfe5cf7 Bump version to 0.9.20 2021-06-14 18:06:27 -04:00
Joshua Boniface ef1701b4c8 Handle an additional exception case 2021-06-14 17:15:40 -04:00
Joshua Boniface 08dc756549 Actually disable the pvcapid service
Prevents it from trying to start itself during updates or reboots on
non-primary coordinators.
2021-06-14 17:13:22 -04:00
Joshua Boniface 0a9c0c1ccb Use a nicer reload method on hot schema update
Instead of exiting and trusting systemd to restart us, instead leverage
the os.execv() call to reload the process in the current PID context.

Also improves the log messages so it's very clear what's going on.
2021-06-14 17:10:21 -04:00
Joshua Boniface e34a7d4d2a Handle hot reloads properly
A hot reload isn't possible due to DataWatch and ChildrenWatch
constructs, so we instead need to terminate the daemon to "apply" the
schema update. Thus we use exit code 150 (Application defined in LSB)
and reorder some of the elements of the schema validation to ensure
things happen in the right order.
2021-06-14 12:52:43 -04:00
Joshua Boniface 1f49bfa1b2 Fix name of schema element 2021-06-13 20:56:17 -04:00
Joshua Boniface 647bce2a22 Ensure we don't grab None data 2021-06-13 16:43:25 -04:00
Joshua Boniface 26b1f531e9 Fix bad variable interpolation 2021-06-13 14:37:23 -04:00
Joshua Boniface be9f1e8636 Use more compatible is_alive in thread 2021-06-13 14:36:27 -04:00
Joshua Boniface b694945010 Fix incorrect name bug 2021-06-10 01:11:14 -04:00
Joshua Boniface 058c2ceef3 Convert VXNetworkInstance to new ZK schema handler 2021-06-10 00:36:18 -04:00
Joshua Boniface e7d60260a0 Fix typo in CephInstance path 2021-06-10 00:36:02 -04:00
Joshua Boniface 85aba7cc18 Convert VMInstance to new ZK schema handler 2021-06-09 23:15:08 -04:00
Joshua Boniface 7e42118e6f Adjust lock schema in NodeInstance and VMInstance
Removes a superfluous lock and puts the sync_lock keys in more usable
places.
2021-06-09 22:51:00 -04:00
Joshua Boniface 2704badfbe Convert VMConsole... to new ZK schema handler 2021-06-09 22:08:32 -04:00
Joshua Boniface 450bf6b153 Convert NodeInstance to new ZK schema handler 2021-06-09 22:07:32 -04:00
Joshua Boniface b94fe88405 Convert fencing to new ZK schema handler 2021-06-09 21:29:01 -04:00
Joshua Boniface 610f6e8f2c Convert CephInstance to new ZK schema handler 2021-06-09 21:17:09 -04:00
Joshua Boniface f913f42a6d Replace schema paths with updated zkhandler 2021-06-09 20:29:42 -04:00
Joshua Boniface e475552391 Fix some bugs with hot reload 2021-06-09 00:03:26 -04:00
Joshua Boniface 5540bdc86b Add automatic schema upgrade to nodes
Performs an automatic schema upgrade when all nodes are updated to the
latest version.

Addresses #129
2021-06-08 23:35:39 -04:00
Joshua Boniface 3c102b3769 Add per-node schema tracking
This will allow nodes to start with their own schema versions, and then
be updated simultaneously by the API.

References #129
2021-06-08 23:35:39 -04:00
Joshua Boniface a4aaf89681 Add ZKSchema loading and validation to Daemon
Also removes some previous hack migrations from pre-0.9.19.

Addresses #129
2021-06-08 23:35:39 -04:00
Joshua Boniface 5843d8aff4 Fix fence call to findTargetNode 2021-06-08 23:34:49 -04:00
Joshua Boniface cf96bb009f Bump version to 0.9.19 2021-06-06 01:47:41 -04:00
Joshua Boniface 719954b70b Fix missing list comma 2021-06-06 01:39:43 -04:00
Joshua Boniface 7dea5d2fac Move logger to common, fix buffering 2021-06-01 18:50:26 -04:00
Joshua Boniface 3a5226b893 Add missing flushed output 2021-06-01 18:30:18 -04:00
Joshua Boniface de2ff2e01b Fix removed function args 2021-06-01 17:02:36 -04:00
Joshua Boniface cd75413667 Increase initial lock timer
With the new library the reader seems to be a little too quick, so hold
the write lock for 1 second instead of 1/2 second to ensure it is
caught.
2021-06-01 17:00:11 -04:00
Joshua Boniface 9764090d6d Merge node common with daemon common 2021-06-01 12:22:11 -04:00
Joshua Boniface 12ac3686de Convert missed elements to new zkhandler 2021-06-01 11:57:21 -04:00
Joshua Boniface 5740d0f2d5 Remove obsolete zkhandler.py 2021-06-01 11:55:44 -04:00
Joshua Boniface 889f4cdf47 Convert common to new zkhandler 2021-06-01 11:55:32 -04:00
Joshua Boniface 8f66a8d00e Fix missed zkhandler conversion 2021-06-01 11:53:33 -04:00
Joshua Boniface 6beea0693c Convert fencing to new zkhandler 2021-06-01 11:53:21 -04:00
Joshua Boniface 1c9a7a6479 Convert VXNetworkInstance to new zkhandler 2021-06-01 11:49:39 -04:00
Joshua Boniface 790098f181 Convert VMInstance to new zkhandler 2021-06-01 11:46:27 -04:00
Joshua Boniface 8a4a41e092 Convert NodeInstance to new zkhandler 2021-06-01 11:27:35 -04:00
Joshua Boniface a48bf2d71e More gracefully handle none selectors
Allow selection of "none" as the node selector, and handle this by
always using the cluster default instead of writing it in.
2021-06-01 11:13:13 -04:00
Joshua Boniface a0b9087167 Set Daemon migration selector in zookeeper 2021-06-01 10:52:41 -04:00
Joshua Boniface 33a54cf7f2 Move configuration keys to /config tree 2021-06-01 10:48:55 -04:00
Joshua Boniface d6a8cf9780 Convert MetadataAPIInstance to new zkhandler 2021-05-31 19:55:09 -04:00
Joshua Boniface abd619a3c1 Convert DNSAggregatorInstance to new zkhandler 2021-05-31 19:55:01 -04:00
Joshua Boniface ef5fe78125 Convert CepnInstance to new zkhandler 2021-05-31 19:51:27 -04:00
Joshua Boniface f6d0e89568 Properly add absent node type 2021-05-31 19:26:27 -04:00
Joshua Boniface ede3e88cd7 Modify node daemon root to use updated zkhandler 2021-05-31 03:14:09 -04:00
Joshua Boniface 0c75a127b2 Bump version to 0.9.18 2021-05-23 17:23:10 -04:00
Joshua Boniface 9de14c46fb Bump version to 0.9.17 2021-05-19 17:06:29 -04:00
Joshua Boniface fe15bdb854 Bump version to 0.9.16 2021-05-10 01:13:21 -04:00
Joshua Boniface b851a6209c Catch all other exceptions in subprocess run
Found a rare glitch where the subprocess pipes would not engage, causing
a daemon crash. Catch these exceptions with a retcode of 255 instead of
bailing out.

Closes #124
2021-05-10 01:07:25 -04:00
Joshua Boniface 5ceb57e540 Handle emptying corrupted console log files
Libvirt will someones write junk out to console log files, which breaks
the log parser deque with a UnicodeDecodeError.

If this happens, clear the log and re-open the deque again for newer
updates.

Closes #123
2021-05-10 01:03:04 -04:00
Joshua Boniface 669338c22b Bump version to 0.9.15 2021-04-08 13:37:47 -04:00
Joshua Boniface c4ac75b973 Bump version to 0.9.14 2021-03-30 10:27:37 -04:00
Joshua Boniface 0bf276fd51 Update copyright year in headers 2021-03-25 17:01:55 -04:00
Joshua Boniface f4ec161aa2 Update file copyright header.
Remove the option to select a later version of the GPL.
2021-03-25 16:58:02 -04:00
Joshua Boniface 0ccfc41398 Bump version to 0.9.13 2021-02-17 11:37:59 -05:00
Joshua Boniface 9100c63e99 Add stored_bytes to pool stats information 2021-02-09 01:46:01 -05:00
Joshua Boniface aba567d6c9 Add nice startup banners to both daemons
Add nicer easy-to-find (yay ASCII art) banners for the startup printouts
of both the node and API daemons. Also adds the safe loader to pvcnoded
to prevent hassle messages and a version string in the API daemon file.
2021-02-08 02:51:43 -05:00
Joshua Boniface 0db8fd9da6 Bump version to 0.9.12 2021-01-28 16:29:58 -05:00
Joshua Boniface 9fbe35fd24 Bump version to 0.9.11 2021-01-05 15:58:26 -05:00
Joshua Boniface a24724d9f0 Use external ceph cmd for ceph df 2020-12-26 14:04:21 -05:00
Joshua Boniface 78c017d51d Remove erroneous extra colon in log output 2020-12-20 16:06:35 -05:00
Joshua Boniface 1b6613c280 Add live VNC information to domain output
Sets in the node daemon, returns via the API, and shows in the CLI,
information about the live VNC listen address and port for VNC-enabled
VMs.

Closes #115
2020-12-20 16:00:55 -05:00
Joshua Boniface d6ef722997 Fix bad log message 2020-12-15 10:51:52 -05:00
Joshua Boniface 518d699c15 Bump version to 0.9.10 2020-12-15 10:45:15 -05:00
Joshua Boniface ac3ef3d792 Revamp fencing order
Prevents unnecessarily excessive timeouts if IPMI connections time out;
before, would have to go through 3 timed out commands at ~20s each
before failure was registered; reduced to 1 if the first times out.
2020-12-15 02:48:25 -05:00
Joshua Boniface 3705daff43 Better handle failing RBD lock frees
If the VM is not in a stop state, failing to free the lock is now
considered a fatal error and will put the domain into fail state,
aborting the start. This is better than being unsafe or trying to start
a VM which will fail to boot due to read-only volumes.
2020-12-14 16:04:38 -05:00
Joshua Boniface 7c99a7bda7 Safely reset RBD locks on failed VMs
Should correct issues on cold start as well as if a VM crashes
uncleanly, which would prevent the VM from starting due to stale RBD
locks.

This implementation has four parts:
  1. Update how IP addresses are handled, specifically by replacing all
  previous instances of "vni_ipaddr" with "vni_floatingipaddr", and then
  adding the "vni_ipaddr" with the real data for this node's IPs. Also
  include the storage IPs in this where they weren't before, so each
  this_node actually has the local IPs plus floating IPs. This enables
  the next two steps.
  2. Modify flush_locks to take this_node as an argument, and update the
  run_command function to only operate against this node, rather than on
  the primary coordinator.
  3. Have the flush_locks check each lock against the current node, to
  verify that the lock is actually held by the current node. This is the
  only way to do this safely. During fencing, we override this by not
  passing a this_node which bypasses this check.
  4. Have the VM start do the check for VM failure/startup and execute a
  flush_locks before actually starting the VM.
2020-12-14 15:53:18 -05:00
Joshua Boniface 89c7e225a0 Move OSD stats uploading to primary only
Instead of each node uploading its own OSD stats, which would not work
if the PVC daemon wasn't running, instead have the primary upload stats
for all OSDs in the cluster.
2020-12-09 02:46:09 -05:00
Joshua Boniface b36ec43a2d Bump version to 0.9.9 2020-12-09 02:20:20 -05:00
Joshua Boniface ce5ee11841 Bump version to 0.9.8 2020-11-24 12:26:57 -05:00
Joshua Boniface d4a28d7a58 Bump version to 0.9.7 2020-11-19 10:48:28 -05:00
Joshua Boniface e69eb93cb3 Bump version to 0.9.6 2020-11-17 13:01:54 -05:00
Joshua Boniface 70dfcd434f Ensure inmigrate is cleared on failure 2020-11-17 12:57:37 -05:00
Joshua Boniface a4e5323e81 Bump version to 0.9.5 2020-11-17 12:34:04 -05:00
Joshua Boniface 9053edacd8 Bump version to 0.9.4 2020-11-10 15:33:50 -05:00
Joshua Boniface baac8f24fd Bump version to 0.9.3 2020-11-09 10:28:15 -05:00
Joshua Boniface 11702f4bc8 Bump version to 0.9.2 2020-11-08 02:03:29 -05:00
Joshua Boniface 6f66b77a00 Lint: E121/E126 continuation line under/over-indented for hanging indent 2020-11-07 15:06:21 -05:00
Joshua Boniface 9135c5e3e4 Lint: E241 multiple spaces after ',' 2020-11-07 14:52:39 -05:00
Joshua Boniface 260b39ebf2 Lint: E302 expected 2 blank lines, found X 2020-11-07 14:45:24 -05:00
Joshua Boniface ab0b932fe3 Lint: E125 continuation line with same indent as next logical line 2020-11-07 13:49:54 -05:00
Joshua Boniface f5988ad53d Lint: F821 undefined name 'pool'/'volume'
This class is actually entirely unused but is kept for consistency with
the others. It may be used someday for something.
2020-11-07 13:34:18 -05:00
Joshua Boniface c3dfe2e381 Lint: F821 undefined name 'myshorthostname' 2020-11-07 13:31:19 -05:00
Joshua Boniface 961ebb4c01 Lint: E305 expected 2 blank lines after class or function definition, found X 2020-11-07 13:17:49 -05:00
Joshua Boniface e553c5d42a Lint: E122 continuation line missing indentation or outdented 2020-11-07 13:12:26 -05:00
Joshua Boniface 7932be3948 Lint: E261 at least two spaces before inline comment 2020-11-07 13:11:03 -05:00
Joshua Boniface d2490419c5 Lint: E202 whitespace before ']' 2020-11-07 13:02:54 -05:00
Joshua Boniface d2e5ede399 Lint: E202 whitespace before ')' 2020-11-07 12:58:54 -05:00
Joshua Boniface 3f242cd437 Lint: E202 whitespace before '}' 2020-11-07 12:57:42 -05:00
Joshua Boniface b7daa8e1f6 E201 whitespace after '[' 2020-11-07 12:39:59 -05:00
Joshua Boniface c88965e898 Lint: E201 whitespace after '(' 2020-11-07 12:39:27 -05:00
Joshua Boniface e333f2b935 Lint: E201 whitespace after '{' 2020-11-07 12:38:31 -05:00
Joshua Boniface 3cb92fed75 Lint: E401 multiple imports on one line 2020-11-07 12:29:32 -05:00
Joshua Boniface 27c6ac2b66 Lint: W605 invalid escape sequence '\d'
This is the only one where forcing an `r` type to the string was
required; the remainder of W605 were replaced with character class
enclosures.
2020-11-07 12:22:20 -05:00
Joshua Boniface 8ba267a59e Lint: E211 whitespace before '['/'(' 2020-11-07 12:20:01 -05:00
Joshua Boniface 39cc992e9b Lint: E306 expected 1 blank line before a nested definition, found 0 2020-11-07 12:17:38 -05:00
Joshua Boniface 8c623023d5 Lint: F811 redefinition of unused '<function>' 2020-11-07 12:14:29 -05:00
Joshua Boniface 5b3ee363b2 Lint: E222 multiple spaces after operator 2020-11-07 12:10:24 -05:00
Joshua Boniface fad27a7f4d Lint: E131 continuation line unaligned for hanging indent 2020-11-06 22:29:49 -05:00
Joshua Boniface 2eef6a1c21 Lint: E265 block comment should start with '# ' 2020-11-06 21:32:17 -05:00
Joshua Boniface 4b47a2424c Lint: E303 too many blank lines (2) 2020-11-06 21:16:52 -05:00
Joshua Boniface cb2defbde9 Lint: W391 blank line at end of file 2020-11-06 21:14:19 -05:00
Joshua Boniface 5da314902f Lint: F841 local variable '<variable>' is assigned to but never used 2020-11-06 21:13:13 -05:00
Joshua Boniface 98a573bbc7 Lint: E402 module level import not at top of file 2020-11-06 20:40:32 -05:00
Joshua Boniface aecb845d6a Lint: E713 test for membership should be 'not in' 2020-11-06 20:37:52 -05:00
Joshua Boniface fde8ea2fea Lint: W291 trailing whitespace 2020-11-06 19:44:14 -05:00
Joshua Boniface 57c51d3234 Lint: E711 comparison to None should be 'if cond is not None:' 2020-11-06 19:37:13 -05:00
Joshua Boniface ce01b41d81 Lint: E711 comparison to None should be 'if cond is None:' 2020-11-06 19:36:36 -05:00
Joshua Boniface 4d6f36aca0 Lint: E712 comparison to False should be 'if cond is False:' or 'if not cond:' 2020-11-06 19:35:51 -05:00
Joshua Boniface fb4aafcea9 Lint: E111 indentation is not a multiple of four 2020-11-06 19:26:22 -05:00
Joshua Boniface d9e7b7ec15 Lint: F401 <library> imported but unused 2020-11-06 19:22:49 -05:00
Joshua Boniface ebf254f62d Lint: W293 blank line contains whitespace 2020-11-06 19:11:07 -05:00
Joshua Boniface 63f4f9aed7 Lint: E722 do not use bare 'except' 2020-11-06 18:55:10 -05:00
Joshua Boniface 56ba7b1457 Bump version to 0.9.1 2020-10-29 12:16:38 -04:00
Joshua Boniface ec0b8acf90 Support per-VM migration type selectors
Allow a VM to specify its migration type as a default choice. The valid
options are "default" (i.e. behave as now), "live" which forces a live
migration only, and "shutdown" which forces a shutdown migration only.
The new option is treated as a VM meta option and is set to default if
not found.
2020-10-29 12:01:29 -04:00
Joshua Boniface 5d08ad9573 Fix incorrect keepalive interval setting 2020-10-26 11:44:45 -04:00
Joshua Boniface 0f299777f1 Modify version to 3-digit numbering
I expect 0.9 will be fairly long-lived, so add another decimal place so
I may continue adding tweaks to it.

THIS IS NOT SEMVER.
2020-10-26 02:13:11 -04:00
Joshua Boniface 890023cbfc Make sender wait dynamic based on receiver 2020-10-21 14:43:54 -04:00
Joshua Boniface 28abb018e3 Improve some timeouts and conditionals 2020-10-21 12:00:10 -04:00
Joshua Boniface 017953c2e6 Move lock release to phase D 2020-10-21 11:07:01 -04:00
Joshua Boniface 82b4d3ed1b Add missing prefix statements to loggers 2020-10-21 10:52:53 -04:00
Joshua Boniface bae366a316 Add waits and only receive check on send 2020-10-21 10:43:42 -04:00
Joshua Boniface 351076c15e Check if node changed during final check
Avoids situations where two migrates, to different nodes, happen in
rapid succession. Aborts the migration if the current target node no
longer matches what was set at the start of the execution.
2020-10-21 02:52:36 -04:00
Joshua Boniface 42514b9a50 Improve messages further 2020-10-21 02:41:42 -04:00
Joshua Boniface 611e47f338 Add messages to migration aborts
Results in some information duplication, but ensures logging of the
reason a migration was aborted separate from the error(s) this may
generate.
2020-10-21 02:38:42 -04:00
Joshua Boniface 1523959074 Move where setting last_ vars happens 2020-10-21 02:24:00 -04:00
Joshua Boniface ef762359f4 Adjust timing to avoid migrating to self quickly
Add another separate state lock, release it earlier, and ensure timings
are good to avoid double-migrating one VM.
2020-10-21 02:17:55 -04:00
Joshua Boniface 398d33778f Avoid stopping duplicates, just lock our own key 2020-10-20 16:10:39 -04:00
Joshua Boniface a6d492ed9f Remove spurious writes and adjust sleep 2020-10-20 16:04:26 -04:00
Joshua Boniface 11fa3b0df3 Remove additional wait and add last_node entries
These allow for aborting a migration to retain the previous settings and
override what the client set.
2020-10-20 15:58:55 -04:00
Joshua Boniface 442aa4e420 Tweak timers further 2020-10-20 15:43:59 -04:00
Joshua Boniface 3910843660 Add missing break 2020-10-20 15:39:29 -04:00
Joshua Boniface 70f3fdbfb9 Tweak the delays slightly on receive 2020-10-20 15:38:07 -04:00
Joshua Boniface 7cb0241a12 Attempt live migrates 3 times before proceeding 2020-10-20 15:33:41 -04:00
Joshua Boniface 9fb33ed7a7 Increase peer lock acquiring timers 2020-10-20 15:26:59 -04:00
Joshua Boniface abfe0108ab Better handle aborting migrations 2020-10-20 15:22:16 -04:00
Joshua Boniface 567fe8f36b Wait for existing migrations before proceeding 2020-10-20 15:12:32 -04:00
Joshua Boniface ec7b78b9b8 Add additional short sleep in receive 2020-10-20 13:29:17 -04:00
Joshua Boniface 224c8082ef Alter text of synchronization messages 2020-10-20 13:08:18 -04:00
Joshua Boniface f9e7e9884f Improve handling of VM migrations
The VM migration code was very old, very spaghettified, and prone to
strange failures.

Improve this by taking cues from the node primary migration. Use
synchronization between the nodes to ensure lockstep completion of the
migration in discrete steps.

A proper queue can be built later to integrate with this code more
cleanly.

References #108
2020-10-20 13:01:55 -04:00
Joshua Boniface 726501f4d4 Add additional logging to flush selector
Adds additional debug logging to the flush selector to determine how any
why any given node is selected. Useful for troubleshooting strange
choices.
2020-10-20 12:34:18 -04:00
Joshua Boniface c6e34c7dc6 Bump base version to 0.9 2020-10-18 14:31:19 -04:00
Joshua Boniface f749633f7c Use provisioned memory for mem migration selector
Use the new "provisioned" memory field, instead of the "allocated"
memory field, to determine the optimal node when using the "mem"
migration selector. This will take into account non-running VMs in the
calculation as well as running VMs.
2020-10-18 14:17:15 -04:00
Joshua Boniface a4b80be5ed Add provisioned memory to node info
Adds a separate field to the node memory, "provisioned", which totals
the amount of memory provisioned to all VMs on the node, regardless of
state, and in contrast to "allocated" which only counts running VMs.

Allows for the detection of potential overprovisioned states when
factoring in non-running VMs.

Includes the supporting code to get this data, since the original
implementation of VM memory selection was dependent on the VM being
running and getting this from libvirt. Now, if the VM is not active, it
gets this from the domain XML instead.
2020-10-18 14:17:15 -04:00
Joshua Boniface aa5f8c93fd Entirely disable IPv6 on bridged interfaces
Prevents any potential leakage due to autoconfigured IPv6 on bridged
interfaces. These are exclusively VM-side bridges, and the PVC host
should not have any IPv6 configuration on them, ever.
2020-10-15 11:00:59 -04:00
Joshua Boniface 9366977fe6 Copy d_domain before iterating
Prevents a bug where the thread can crash due to a change in the
d_domain object while running the for loop. By copying and iterating
over the copy, this becomes safer.
2020-09-16 15:12:37 -04:00
Joshua Boniface 65b44f2955 Avoid breaking keepalive during incoming migration
The keepalive was getting stuck gathering memoryStats from the
non-running VM, since it was in a paused state. Avoid this by just
skipping past the rest of the stats gathering if the VM isn't running.
2020-08-28 01:47:36 -04:00
Joshua Boniface 78dec77987 Bump version to 0.8 2020-08-26 10:24:44 -04:00
Joshua Boniface 921e57ca78 Fix syntax error 2020-08-20 23:05:56 -04:00
Joshua Boniface 3cc7df63f2 Add configurable VM shutdown timeout
Closes #102
2020-08-20 21:26:12 -04:00
Joshua Boniface e8e65934e3 Use logger prefix for thread debug logs 2020-08-17 14:30:21 -04:00
Joshua Boniface 24fda8a73f Use new debug logger for DNS Aggregator 2020-08-17 14:26:43 -04:00
Joshua Boniface 9b3ef6d610 Add connect timeout to Ceph
This doesn't seem to actually do anything (like most of these
timeouts...) but add it just for posterity.
2020-08-17 13:58:14 -04:00
Joshua Boniface b451c0e8e3 Add additional start/finish debug messages 2020-08-17 13:11:03 -04:00
Joshua Boniface f9b126a106 Make zkhandler accept failures more robustly
Most of these would silently fail if there was e.g. an issue with the ZK
connection. Instead, encase things in try blocks and handle the
exceptions in a more graceful way, returning None or False if
applicable. Except for locks, which should retry 5 times before
aborting.
2020-08-17 13:03:36 -04:00
Joshua Boniface 553f96e7ef Use logger for debug output
Using simple print statements was annoying (lack of timing info and
formatting), so move to using the debug logger for these instead with a
custom state ('d') with white text to differentiate them. Also indicate
which subthread of the keepalive each task is being executed in for
easier tracing of issues.
2020-08-17 12:46:52 -04:00
Joshua Boniface 65add58c9a Properly properly handle issue 2020-08-16 11:38:39 -04:00
Joshua Boniface 0a01d84290 Tie fence timers to keepalive_interval
Also wait 2 full keepalive intervals after fencing before doing anything
else, to give the Ceph cluster a chance to recover.
2020-08-15 12:38:03 -04:00
Joshua Boniface 4afb288429 Properly handle missing domain_name fail 2020-08-15 12:07:23 -04:00
Joshua Boniface 985ad5edc0 Warn if fencing will fail
Verify our IPMI state on startup, and then warn if fencing will fail.
For now, this is sufficient, but in future (requires refactoring) we
might want to adjust how fencing occurs based on this information.
2020-08-13 14:42:18 -04:00
Joshua Boniface 0587bcbd67 Go back to manual command for OSD stats
Using the Ceph library was a disaster here; it had no timeout or way to
force it to continue, so keepalives would become stuck and trigger fence
storms. Go back to the manual osd dump command with a 2s timeout which
is far more reliable and can be adequately terminated if it runs long.
2020-08-12 22:31:25 -04:00
Joshua Boniface e0cb4a58c3 Ensure zk_listener is readded after reconnect 2020-08-11 12:46:15 -04:00
Joshua Boniface 099c58ead8 Fix missing char in log message 2020-08-11 12:40:35 -04:00
Joshua Boniface 0e5c681ada Clean up imports
Make several imports more specific to reduce redundant code imports and
improve memory utilization.
2020-08-11 12:09:10 -04:00
Joshua Boniface 46ffe352e3 Better handle subthread timeouts in keepalive
Prevent the main keepalive thread from getting stuck due to a subthread
taking an enormous time. If this happens, the rest of the main keepalive
will continue onward, thus ensuring that the main keepalive does not
fail for a significant number of cycles, which would cause a fence.
2020-08-11 11:37:26 -04:00
Joshua Boniface ccee124c8b Adjust fence failcount limit to 6 (30s)
The previous saving throw limit (3/15s) seems to have been too low. I
was observing bizarre failures where a node would be fenced while it was
still starting up. Some of this may have been related to Zookeeper
connections taking too long, but this was inconsistent.

Increase this to 6 saving throws (30s). This provides significantly more
time for a node to properly check in on startup before another node
fences it. In the real world, 15s vs 30s isn't that big of a downtime
change, but prevents false-positive fences.
2020-08-05 22:40:07 -04:00
Joshua Boniface 02343079c0 Improve fencing migrate layout
Open the option to do this in parallel with some threads
2020-08-05 22:26:01 -04:00
Joshua Boniface 37b83aad6a Add logging and use better conditional 2020-08-05 21:57:36 -04:00
Joshua Boniface 876f2424e0 Ensure dead state isn't written erroneously 2020-08-05 21:57:11 -04:00
Joshua Boniface 5871380e1b Avoid crashing VM stats thread if domain migrated 2020-06-10 17:10:46 -04:00
Joshua Boniface 654a3cb7fa Improve debug output and use ceph df util data 2020-06-06 22:52:49 -04:00
Joshua Boniface 9b65d3271a Improve handling of Ceph status gathering
Use the Rados library instead of random OS commands, which massively
improves the performance of these tasks.

Closes #97
2020-06-06 22:30:25 -04:00
Joshua Boniface 598b2025e8 Use Rados and add Ceph entries to pvcnoded.yaml 2020-06-06 21:12:51 -04:00
Joshua Boniface 70b787d1fd Move all VM functions into thread 2020-06-06 15:44:05 -04:00
Joshua Boniface e1310a05f2 Implement recording of VM stats during keepalive 2020-06-06 15:34:03 -04:00
Joshua Boniface 2ad6860dfe Move Ceph statistics gathering into thread 2020-06-06 13:25:02 -04:00
Joshua Boniface cebb4bbc1a Comment cleanup 2020-06-06 13:20:40 -04:00
Joshua Boniface a672e06dd2 Move fencing to end of keepalive function 2020-06-06 13:19:11 -04:00
Joshua Boniface 1db73bb892 Move libvirt closure into previous section 2020-06-06 13:18:37 -04:00
Joshua Boniface c1956072f0 Rename update_zookeeper function to node_keepalive 2020-06-06 12:49:50 -04:00
Joshua Boniface ce60836c34 Allow enforcement of live migration
Provides a CLI and API argument to force live migration, which triggers
a new VM state "migrate-live". The node daemon VMInstance during migrate
will read this flag from the state and, if enforced, will not trigger a
shutdown migration.

Closes #95
2020-06-06 12:00:44 -04:00
Joshua Boniface b5434ba744 Fix typo in variable name 2020-06-06 11:29:48 -04:00
Joshua Boniface b9e5b14f94 Update lastnode too if a self-migrate is aborted
References #92
2020-06-04 10:28:04 -04:00
Joshua Boniface 5d2031d99e Prevent a VM migrating to the same node
Prevents a rare edge case where a node can end up "migrating" to itself.
Quick hack to fix this, though like most of the VM management should
probably be rethought/rewritten later.

Fixes #92
2020-06-04 10:26:47 -04:00
Joshua Boniface 5f9836f96d Add error message to OSD parse fail 2020-05-12 11:04:38 -04:00
Joshua Boniface 95c59ba629 Improve flush handling slightly 2020-05-12 11:04:38 -04:00
Joshua Boniface 72a38fd437 Correct changed dhcp_reservations key name 2020-05-09 10:00:53 -04:00
Joshua Boniface b580760537 Add missing fmt_cyan variable 2020-05-08 18:15:02 -04:00
Joshua Boniface 331027d124 Add further tweaks to takeover state checks
Just ensure that everything is proper state before proceeding
2020-04-22 11:16:19 -04:00
Joshua Boniface 611e0edd80 Reorder last keepalive during cleanup
Make sure the stopping of the keepalive timer and final keepalive update
are done as the last step before complete shutdown. The previous setup
could conceivably result in a node being fenced should the cleanup
operations take longer than ~45 seconds, for instance if primary node
switchover took too long or blocked, or log watchers failed to stop
quickly enough. Ensures that keepalives will continue to be run during
the shutdown process until the last possible moment.
2020-04-12 03:49:29 -04:00
Joshua Boniface b413e042a6 Improve handling of primary contention
Previously, contention could occasionally cause a flap/dual primary
contention state due to the lack of checking within this function. This
could cause a state where a node transitions to primary than is almost
immediately shifted away, which could cause undefined behaviour in the
cluster.

The solution includes several elements:
    * Implement an exclusive lock operation in zkhandler
    * Switch the become_primary function to use this exclusive lock
    * Implement exclusive locking during the contention process
    * As a failsafe, check stat versions before setting the node as the
      primary node, in case another node already has
    * Delay the start of takeover/relinquish operations by slightly
      longer than the lock timeout
    * Make the current router_state conditions more explicit (positive
      conditionals rather than negative conditionals)

The new scenario ensures that during contention, only one secondary will
ever succeed at acquiring the lock. Ideally, the other would then grab
the lock and pass, but in testing this does not seem to be the case -
the lock always times out, so the failsafe check is technically not
needed but has been left as an added safety mechanism. With this setup,
the node that fails the contention will never block the switchover nor
will it try to force itself onto the cluster after another node has
successfully won contention.

Timeouts may need to be adjusted in the future, but the base timeout of
0.4 seconds (and transition delay of 0.5 seconds) seems to work reliably
during preliminary tests.
2020-04-12 03:40:17 -04:00
Joshua Boniface a671d9d457 Use consistent tense in messages 2020-04-08 22:00:51 -04:00
Joshua Boniface fee1c7dd6c Reorder cleanup and gracefully wait for flushes 2020-04-08 22:00:08 -04:00
Joshua Boniface 0a367898a0 Don't trigger aggregator fail if fine 2020-03-12 13:22:12 -04:00
Joshua Boniface c02bc0b46a Correct issues with VM lock freeing
Code was bad and using a depricated feature.
2020-03-02 12:45:12 -05:00
Joshua Boniface 1e4350ca6f Properly handle takeover state in VXNetworks
Most of these actions/conditionals were looking for primary state, but
were failing during node takeover. Update the conditionals to look for
both router states instead.

Also add a wait to lock flushing until a takeover is completed.
2020-03-02 10:41:00 -05:00
Joshua Boniface 57768f2583 Remove an obsolete script 2020-02-19 21:40:23 -05:00
Joshua Boniface e4e4e336b4 Handle invalid cursor setup cleanly
This seems to happen only during termination, so catch it and continue
so the loop terminates.
2020-02-19 16:29:59 -05:00
Joshua Boniface d2a5fe59c0 Use transitional takeover states for migration
Use a pair of transitional states, "takeover" and "relinquish", when
transitioning between primary and secondary coordinator states. This
provides a clsuter-wide record that the nodes are still working during
their synchronous transition states, and should allow clients to
determine when the node(s) have fully switched over. Also add an
additional 2 seconds of wait at the end of the transition jobs to ensure
everything has had a chance to start before proceeding.

References #72
2020-02-19 14:06:54 -05:00
Joshua Boniface 9c7041f12c Update package version to 0.7 2020-02-15 23:25:47 -05:00
Joshua Boniface 7ace5b5056 Remove /ceph/cmd pipe for (most) Ceph commands
Addresses #80
2020-02-08 23:40:02 -05:00
Joshua Boniface ce985234c3 Use consistent naming of components
Rename "pvcd" to "pvcnoded", and "pvc-api" to "pvcapid" so names for the
daemons are fully consistent. Update the names of the configuration
files as well to match this new formatting.

References #79
2020-02-08 19:34:07 -05:00