Commit Graph

756 Commits

Author SHA1 Message Date
Joshua Boniface b5f996febd Fix bugs for node flush for stop/shutdown/restart
Previously VMs in stop/shutdown/restart states wouldn't be properly
handled during a node flush. This fixes the bugs and ensures that the
transient VM states (shutdown/restart) are completed before proceeding,
and then avoids setting a stopped/shutdown VM to shutdown/auotstart.
2023-08-18 11:25:59 -04:00
Joshua Boniface 3a90fda109 Bump version to 0.9.63 2023-04-28 14:47:04 -04:00
Joshua Boniface 9114255af5 Add *.update-* obsolete configs to dpkg plugin 2023-04-10 15:39:40 -04:00
Joshua Boniface 2c3a3cdf52 Use try when watching health value in NodeInstance 2023-03-07 09:53:01 -05:00
Joshua Boniface 0b583bfdaf Bump IPMI timeout to 2 seconds 2023-03-07 09:25:27 -05:00
Joshua Boniface 7c07fbefff Adjust keepalive health printing and ordering 2023-02-24 11:08:30 -05:00
Joshua Boniface 202dc3ed59 Correct error handling if monitoring plugins fail 2023-02-24 10:19:41 -05:00
Joshua Boniface 4c2d99f8a6 Fix bug with SMART info 2023-02-23 13:21:23 -05:00
Joshua Boniface bcff6650d0 Set timeout on IPMI command 2023-02-23 11:10:09 -05:00
Joshua Boniface a11206253d Fix ZK check location 2023-02-23 11:04:02 -05:00
Joshua Boniface 45ad3b9a17 Bump version to 0.9.62 2023-02-22 18:13:45 -05:00
Joshua Boniface dc4e56db4b Add IPMI monitoring check 2023-02-22 15:02:08 -05:00
Joshua Boniface e45b3108a2 Add health delta change to message output 2023-02-22 15:02:08 -05:00
Joshua Boniface 118237a53b Fix bad string value for message 2023-02-22 15:02:08 -05:00
Joshua Boniface 9805681f94 Use consistent connection with other checks 2023-02-22 15:02:08 -05:00
Joshua Boniface 6c9abb2abe Add Libvirtd monitoring check 2023-02-22 15:02:08 -05:00
Joshua Boniface a1122c6e71 Add Zookeeper monitoring check 2023-02-22 15:02:08 -05:00
Joshua Boniface 3696f81597 Add PostgreSQL monitoring check 2023-02-22 15:02:08 -05:00
Joshua Boniface 5ca0d903b6 Adjust comment message 2023-02-22 15:02:08 -05:00
Joshua Boniface 626424b74a Adjust Munin threshold values 2023-02-22 10:42:43 -05:00
Joshua Boniface c9ceb3159b Remove obsolete LINKSPEED variable 2023-02-22 01:04:25 -05:00
Joshua Boniface 6525a2568b Adjust health delta of load to 50
This is a very bad situation and should be critical.
2023-02-22 01:03:12 -05:00
Joshua Boniface 09a005d3d7 Adjust health delta of EDAC Uncorrected to 50
This is a very bad situation and should be critical.
2023-02-22 01:01:54 -05:00
Joshua Boniface fb0fcc0597 Update readme for Munin plugin 2023-02-18 00:00:04 -05:00
Joshua Boniface 3009f24910 Fix typo in var and flip conditional 2023-02-17 16:18:42 -05:00
Joshua Boniface 5ae836f1c5 Fix various issues with PVC Munin plugin 2023-02-17 15:41:16 -05:00
Joshua Boniface eda1b95d5f Update Munin plugin example 2023-02-16 16:06:00 -05:00
Joshua Boniface 3bd93563e6 Add CheckMK monitoring example plugins 2023-02-16 16:05:47 -05:00
Joshua Boniface 1093ca6264 Disallow health less than 0 2023-02-15 16:50:24 -05:00
Joshua Boniface 388f6556c0 Remove extra text from packages plugin 2023-02-15 16:28:41 -05:00
Joshua Boniface 6c7be492b8 Move Ceph health to global cluster health 2023-02-15 15:46:13 -05:00
Joshua Boniface f4eef30770 Add JSON health to cluster data 2023-02-15 15:26:57 -05:00
Joshua Boniface 8565cf26b3 Add disk monitoring plugin 2023-02-15 11:30:49 -05:00
Joshua Boniface 0ecf219910 Run setup during plugin loads 2023-02-15 10:11:38 -05:00
Joshua Boniface 0f4edc54d1 Use percentage in keepalie output 2023-02-15 01:56:02 -05:00
Joshua Boniface ca91be51e1 Improve ethtool parsing speeds 2023-02-14 15:49:58 -05:00
Joshua Boniface e29d0e89eb Add NIC monitoring plugin 2023-02-14 15:43:52 -05:00
Joshua Boniface 14d29f2986 Adjust text on log message 2023-02-13 22:21:23 -05:00
Joshua Boniface bc88d764b0 Add logging flag for montioring plugin output 2023-02-13 22:04:39 -05:00
Joshua Boniface a3c31564ca Flip condition in EDAC check 2023-02-13 21:58:56 -05:00
Joshua Boniface b07396c39a Fix bugs if plugins fail to load 2023-02-13 21:51:48 -05:00
Joshua Boniface 71139fa66d Add EDAC check plugin 2023-02-13 21:43:13 -05:00
Joshua Boniface 1ea4800212 Set node health to None when restarting 2023-02-13 15:54:46 -05:00
Joshua Boniface 9c14d84bfc Add node health value and send out API 2023-02-13 15:53:39 -05:00
Joshua Boniface d8f346abdd Move Ceph cluster health reporting to plugin
Also removes several outputs from the normal keepalive that were
superfluous/static so that the main output fits on one line.
2023-02-13 13:29:40 -05:00
Joshua Boniface 2ee52e44d3 Move Ceph cluster health reporting to plugin
Also removes several outputs from the normal keepalive that were
superfluous/static so that the main output fits on one line.
2023-02-13 12:13:56 -05:00
Joshua Boniface 3c742a827b Initial implementation of monitoring plugin system 2023-02-13 12:06:26 -05:00
Joshua Boniface aeb238f43c Bump version to 0.9.61 2023-02-08 10:08:05 -05:00
Joshua Boniface a49510ecc8 Bump version to 0.9.60 2022-12-06 15:42:55 -05:00
Joshua Boniface 92feeefd26 Bump version to 0.9.59 2022-11-15 15:50:15 -05:00
Joshua Boniface 38d63d9837 Flip behaviour of memory selectors
It didn't make any sense to me for mem(prov) to be the default selector,
since this has too many caveats versus mem(free). Switch to using
mem(free) as the default (i.e. "mem") and make memprov the alternative.
2022-11-15 15:45:59 -05:00
Joshua Boniface 095bcb2373 Bump version to 0.9.58 2022-11-07 12:27:48 -05:00
Joshua Boniface d65f512897 Bump version to 0.9.57 2022-11-06 01:39:50 -04:00
Joshua Boniface c3bc55eff8 Bump version to 0.9.56 2022-10-27 14:21:04 -04:00
Joshua Boniface 6c58d52fa1 Add node autoready oneshot unit
This replicates some of the more important functionality of the defunct
pvc-flush.service unit. On presence of a trigger file (i.e.
/etc/pvc/autoready), it will trigger a "node ready" on boot. It does
nothing on shutdown as this must be handled by other mechanisms, though
a similar autoflush could be added as well.
2022-10-27 14:09:14 -04:00
Joshua Boniface 726d0a562b Update copyright header year 2022-10-06 11:55:27 -04:00
Joshua Boniface f1df1cfe93 Bump version to 0.9.55 2022-10-04 13:21:40 -04:00
Joshua Boniface 5942aa50fc Avoid raise/handle deadlocks
Can cause log flooding in some edge cases and isn't really needed any
longer. Use a proper conditional followed by an actual error handler.
2022-10-03 14:04:12 -04:00
Joshua Boniface 239c392892 Bump version to 0.9.54 2022-08-23 11:01:05 -04:00
Joshua Boniface 9b499b9f48 Bump version to 0.9.53 2022-08-12 17:47:11 -04:00
Joshua Boniface 2a21d48128 Bump version to 0.9.52 2022-08-12 11:09:25 -04:00
Joshua Boniface 8d0f26ff7a Add additional kb_ values to OSD stats
Allows for easier parsing later to get e.g. % values and more details on
the used amounts.
2022-08-11 11:06:36 -04:00
Joshua Boniface 645b525ad7 Bump version to 0.9.51 2022-07-25 23:25:41 -04:00
Joshua Boniface ec559aec0d Remove pvc-flush service
This service caused more headaches than it was worth, so remove it.

The original goal was to cleanly flush nodes on shutdown and unflush
them on startup, but this is tightly controlled by Ansible playbooks at
this point, and this is something best left to the Administrator and
their particular situation anyways.
2022-07-25 23:21:34 -04:00
Joshua Boniface 932b3c55a3 Bump version to 0.9.50 2022-07-06 16:01:14 -04:00
Joshua Boniface 92e2ff7449 Fix bug with space-containing detect strings 2022-07-06 15:58:57 -04:00
Joshua Boniface f8cdcb30ba Add migration selector via free memory
Closes #152
2022-05-18 03:47:16 -04:00
Joshua Boniface 51ad2058ed Bump version to 0.9.49 2022-05-06 15:49:39 -04:00
Joshua Boniface 7a40c7a55b Add support for replacing/refreshing OSDs
Adds commands to both replace an OSD disk, and refresh (reimport) an
existing OSD disk on a new node. This handles the cases where an OSD
disk should be replaced (either due to upgrades or failures) or where a
node is rebuilt in-place and an existing OSD must be re-imported to it.

This should avoid the need to do a full remove/add sequence for either
case.

Also cleans up some aspects of OSD removal that are identical between
methods (e.g. using safe-to-destroy and sleeping after stopping) and
fixes a bug if an OSD does not truly exist when the daemon starts up.
2022-05-06 15:32:06 -04:00
Joshua Boniface 3801fcc07b Fix bug with initial JSON for stats 2022-05-02 13:28:19 -04:00
Joshua Boniface c741900baf Refactor OSD removal to use new ZK data
With the OSD LVM information stored in Zookeeper, we can use this to
determine the actual block device to zap rather than relying on runtime
determination and guestimation.
2022-05-02 12:52:22 -04:00
Joshua Boniface 464f0e0356 Store additional OSD information in ZK
Ensures that information like the FSIDs and the OSD LVM volume are
stored in Zookeeper at creation time and updated at daemon start time
(to ensure the data is populated at least once, or if the /dev/sdX
path changes).

This will allow safer operation of OSD removals and the potential
implementation of re-activation after node replacements.
2022-05-02 12:11:39 -04:00
Joshua Boniface cea8832f90 Ensure initial OSD stats is populated
Values are all invalid but this ensures the client won't error out when
trying to show an OSD that has never checked in yet.
2022-04-29 16:50:30 -04:00
Joshua Boniface 5807351405 Bump version to 0.9.48 2022-04-29 15:03:52 -04:00
Joshua Boniface d6ca74376a Fix bugs with forced removal 2022-04-29 14:03:07 -04:00
Joshua Boniface 4d698be34b Add OSD removal force option
Ensures a removal can continue even in situations where some step(s)
might fail, for instance removing an obsolete OSD from a replaced node.
2022-04-29 11:16:33 -04:00
Joshua Boniface ea709f573f Bump version to 0.9.47 2021-12-28 22:03:08 -05:00
Joshua Boniface 58d57d7037 Bump version to 0.9.46 2021-12-28 15:02:14 -05:00
Joshua Boniface 00d2c67c41 Allow single-node clusters to restart and timeout
Prevents a daemon from waiting forever to terminate if it is primary,
and avoids this entirely if there is only a single node in the cluster.
2021-12-28 03:06:03 -05:00
Joshua Boniface 67131de4f6 Fix bug when removing OSDs
Ensure the OSD is down as well as out or purge might fail.
2021-12-28 03:05:34 -05:00
Joshua Boniface abc23ebb18 Handle detect strings as arguments for blockdevs
Allows specifying blockdevs in the OSD and OSD-DB addition commands as
detect strings rather than actual block device paths. This provides
greater flexibility for automation with pvcbootstrapd (which originates
the concept of detect strings) and in general usage as well.
2021-12-28 02:53:02 -05:00
Joshua Boniface f164d898c1 Bump version to 0.9.45 2021-11-25 09:34:20 -05:00
Joshua Boniface a8899a1d66 Fix ordering of pvcnoded unit
We want to be after network.target and want network-online.target
2021-11-18 16:56:49 -05:00
Joshua Boniface 817dffcf30 Bump version to 0.9.44 2021-11-11 16:20:38 -05:00
Joshua Boniface eda2a57a73 Add Munin plugin for Ceph utilization 2021-11-08 15:21:09 -05:00
Joshua Boniface 6e9fcd38a3 Bump version to 0.9.43 2021-11-08 02:29:17 -05:00
Joshua Boniface 78faa90139 Reformat recent changes with Black 2021-11-06 03:27:07 -04:00
Joshua Boniface 23b1501f40 Fix linting error F541 f-string placeholders 2021-11-06 03:26:03 -04:00
Joshua Boniface 66bfad3109 Fix linting errors F522/F523 unused args 2021-11-06 03:24:50 -04:00
Joshua Boniface c41664d2da Reformat code with Black code formatter
Unify the code style along PEP and Black principles using the tool.
2021-11-06 03:02:43 -04:00
Joshua Boniface 2e7b9b28b3 Add some delay and additional tries to fencing 2021-10-27 16:24:17 -04:00
Joshua Boniface 55f397a347 Fix bad location of config sets 2021-10-12 17:23:04 -04:00
Joshua Boniface dfebb2d3e5 Also validate on failures 2021-10-12 17:11:03 -04:00
Joshua Boniface e88147db4a Bump version to 0.9.42 2021-10-12 15:25:42 -04:00
Joshua Boniface b8204d89ac Go back to passing if exception
Validation already happened and the set happens again later.
2021-10-12 14:21:52 -04:00
Joshua Boniface fe73dfbdc9 Use current live value for bridge_mtu
This will ensure that upgrading without the bridge_mtu config key set
will keep things as they are.
2021-10-12 12:24:03 -04:00
Joshua Boniface 8f906c1f81 Use power off in fence instead of reset
Use a power off (and then make the power on a requirement) during a node
fence. Removes some potential ambiguity in the power state, since we
will know for certain if it is off.
2021-10-12 11:04:27 -04:00
Joshua Boniface 2d9fb9688d Validate network MTU after initial read 2021-10-12 10:53:17 -04:00
Joshua Boniface f13cc04b89 Bump version to 0.9.41 2021-10-09 19:39:21 -04:00
Joshua Boniface 95e01f38d5 Adjust log type of object setup message 2021-10-09 19:23:12 -04:00