Otherwise the node entries could come back in an arbitrary order; since
this is an ordered list of dictionaries that might not be expected by
the API consumers, so ensure it's always sorted.
This service caused more headaches than it was worth, so remove it.
The original goal was to cleanly flush nodes on shutdown and unflush
them on startup, but this is tightly controlled by Ansible playbooks at
this point, and this is something best left to the Administrator and
their particular situation anyways.
1. Add documentation on the node selector flags. In the API, reference
the daemon configuration manual which now includes details in this
section; in the CLI, provide the help in "pvc vm define" in detail and
then reference that command's help in the other commands that use this
field.
2. Ensure the naming is consistent in the CLI, using the flag name
"--node-selector" everywhere (was "--selector" for "pvc vm" commands and
"--node-selector" for "pvc provisioner" commands).
Adds commands to both replace an OSD disk, and refresh (reimport) an
existing OSD disk on a new node. This handles the cases where an OSD
disk should be replaced (either due to upgrades or failures) or where a
node is rebuilt in-place and an existing OSD must be re-imported to it.
This should avoid the need to do a full remove/add sequence for either
case.
Also cleans up some aspects of OSD removal that are identical between
methods (e.g. using safe-to-destroy and sleeping after stopping) and
fixes a bug if an OSD does not truly exist when the daemon starts up.
With the OSD LVM information stored in Zookeeper, we can use this to
determine the actual block device to zap rather than relying on runtime
determination and guestimation.
Ensures that information like the FSIDs and the OSD LVM volume are
stored in Zookeeper at creation time and updated at daemon start time
(to ensure the data is populated at least once, or if the /dev/sdX
path changes).
This will allow safer operation of OSD removals and the potential
implementation of re-activation after node replacements.
If there is...
1. No '--cluster' passed, and
2. No 'local' cluster, and
3. There is exactly one cluster configured
...then use that cluster by default in the CLI.
Allows an administrator to adjust the PG count of a given pool. This can
be used to increase the PGs (for example after adding more OSDs) or
decrease it (to remove OSDs, reduce CPU load, etc.).
Allows specifying a particular device class ("tier") for a given pool,
for instance SSD-only or NVMe-only. This is implemented with Crush
rules on the Ceph side, and via an additional new key in the pool
Zookeeper schema which is defaulted to "default".
Allows specifying blockdevs in the OSD and OSD-DB addition commands as
detect strings rather than actual block device paths. This provides
greater flexibility for automation with pvcbootstrapd (which originates
the concept of detect strings) and in general usage as well.
This ensures that any client command is logged by the local system.
Helps ensure Accounting for users of the CLI. Currently logs the full
command executed along with the $USER environment variable contents.
Solves two problems:
1. How match fuzziness was used was very inconsistent; make them all the
same, i.e. "if is_fuzzy and limit, apply .* to both sides".
2. Use re.fullmatch instead of re.match to ensure exact matching of the
regex to the value. Without fuzziness, this would sometimes cause
inconsistent behavior, for instance if a limit was non-fuzzy "vm",
expecting to match the actual "vm", but also matching "vm1" too.