diff --git a/docs/installing.md b/docs/installing.md index ee2ea287..8a7abfdc 100644 --- a/docs/installing.md +++ b/docs/installing.md @@ -29,6 +29,9 @@ This guide will walk you through setting up a simple 3-node PVC cluster from scr 0. Configure the IPMI user specified in the `pvc-ansible` `group_vars/base.yml` file with the required permissions; this user will be used to reboot the host if it fails, so it must be able to control system power state. +0. Configure IPMI to enable IPMI over LAN. Use the default (all-zero) encryption key; this is needed for fencing to work. Verify that IPMI over LAN is operating by using the following command from a machine able to reach the IPMI interface: + `/usr/bin/ipmitool -I lanplus -H -U -P chassis power status` + 0. Load the installer ISO generated in step 5 of the previous section onto a USB stick, or using IPMI virtual media, on the physical servers. 0. Boot the physical servers off of the installer ISO, in UEFI mode if available for maximum flexibility.