204 lines
12 KiB
YAML
204 lines
12 KiB
YAML
---
|
|
# Logging configuration (uncomment to override defaults)
|
|
# These default options are generally best for most clusters; override these if you want more granular
|
|
# control over the logging output of the PVC system.
|
|
#pvc_log_to_file: False # Log to a file in /var/log/pvc
|
|
#pvc_log_to_stdout: True # Log to stdout (i.e. journald)
|
|
#pvc_log_to_zookeeper: True # Log to Zookeeper (required for 'node log' commands)
|
|
#pvc_log_colours: True # Log colourful prompts for states instead of text
|
|
#pvc_log_dates: False # Log dates (useful with log_to_file, not useful with log_to_stdout as journald adds these)
|
|
#pvc_log_keepalives: True # Log keepalive event every pvc_keepalive_interval seconds
|
|
#pvc_log_keepalive_cluster_details: True # Log cluster details (VMs, load, etc.) duing keepalive events
|
|
#pvc_log_keepalive_storage_details: True # Log storage details (OSDs, pools, health) during keepalive events
|
|
#pvc_log_console_lines: 1000 # The number of VM console log lines to store in Zookeeper for 'vm log' commands.
|
|
#pvc_log_node_lines: 2000 # The number of node log lines to store in Zookeeper for 'node log' commands.
|
|
|
|
# Timing and fencing configuration (uncomment to override defaults)
|
|
# These default options are generally best for most clusters; override these if you want more granular
|
|
# control over the timings of various areas of the cluster, for instance if your hardware is slow or error-prone.
|
|
#pvc_vm_shutdown_timeout: 180 # Number of seconds before a 'shutdown' VM is forced off
|
|
#pvc_keepalive_interval: 5 # Number of seconds between keepalive ticks
|
|
#pvc_fence_intervals: 6 # Number of keepalive ticks before a node is considered dead
|
|
#pvc_suicide_intervals: 0 # Number of keepalive ticks before a node consideres itself dead (0 to disable)
|
|
#pvc_fence_successful_action: migrate # What to do with VMs when a fence is successful (migrate, None)
|
|
#pvc_fence_failed_action: None # What to do with VMs when a fence is failed (migrate, None) - migrate is DANGEROUS without pvc_suicide_intervals set to < pvc_fence_intervals
|
|
#pvc_migrate_target_selector: mem # The selector to use for migrating VMs if not explicitly set; one of mem, memfree, load, vcpus, vms
|
|
|
|
# Client API basic configuration
|
|
pvc_api_listen_address: "{{ pvc_upstream_floatingip }}"
|
|
pvc_api_listen_port: "7370"
|
|
pvc_api_secret_key: "" # Use pwgen to generate
|
|
|
|
# Client API user tokens
|
|
# Create a token (random UUID or password) for each user you wish to have access to the PVC API.
|
|
# The first token will always be used for the "local" connection, and thus at least one token MUST be defined.
|
|
pvc_api_enable_authentication: True
|
|
pvc_api_tokens:
|
|
# - description: "myuser"
|
|
# token: "a3945326-d36c-4024-83b3-2a8931d7785a"
|
|
|
|
# PVC API SSL configuration
|
|
# Use these options to enable SSL for the API listener, providing security over WAN connections.
|
|
# There are two options for defining the SSL certificate and key to use:
|
|
# a) Set both pvc_api_ssl_cert_path and pvc_api_ssl_key_path to paths to an existing SSL combined (CA + cert) certificate and key, respectively, on the system.
|
|
# b) Set both pvc_api_ssl_cert and pvc_api_ssl_key to the raw PEM-encoded contents of an SSL combined (CA + cert) certificate and key, respectively, which will be installed under /etc/pvc.
|
|
# If the _path options are non-empty, the raw entries are ignored and will not be used.
|
|
pvc_api_enable_ssl: False
|
|
pvc_api_ssl_cert_path:
|
|
pvc_api_ssl_cert: >
|
|
# A RAW CERTIFICATE FILE, installed to /etc/pvc/api-cert.pem
|
|
pvc_api_ssl_key_path:
|
|
pvc_api_ssl_key: >
|
|
# A RAW KEY FILE, installed to /etc/pvc/api-key.pem
|
|
|
|
# Ceph storage configuration
|
|
pvc_ceph_storage_secret_uuid: "" # Use uuidgen to generate
|
|
|
|
# Database configuration
|
|
pvc_dns_database_name: "pvcdns"
|
|
pvc_dns_database_user: "pvcdns"
|
|
pvc_dns_database_password: "" # Use pwgen to generate
|
|
pvc_api_database_name: "pvcapi"
|
|
pvc_api_database_user: "pvcapi"
|
|
pvc_api_database_password: "" # Use pwgen to generate
|
|
pvc_replication_database_user: "replicator"
|
|
pvc_replication_database_password: "" # Use pwgen to generate
|
|
pvc_superuser_database_user: "postgres"
|
|
pvc_superuser_database_password: "" # Use pwgen to generate
|
|
|
|
# Network routing configuration
|
|
# > The ASN should be a private ASN number.
|
|
# > The list of routers are those which will learn routes to the PVC client networks via BGP;
|
|
# they should speak BGP and allow sessions from the PVC nodes.
|
|
pvc_asn: "65500"
|
|
pvc_routers:
|
|
- "192.168.100.1"
|
|
|
|
# PVC Node list
|
|
# > Every node configured with this playbook must be specified in this list.
|
|
pvc_nodes:
|
|
- hostname: "pvchv1" # This name MUST match the Ansible inventory_hostname's first portion, i.e. "inventory_hostname.split('.')[0]"
|
|
is_coordinator: yes
|
|
node_id: 1
|
|
router_id: "192.168.100.11"
|
|
upstream_ip: "192.168.100.11"
|
|
cluster_ip: "10.0.0.1"
|
|
storage_ip: "10.0.1.1"
|
|
ipmi_host: "{{ ipmi['hosts']['pvchv1']['hostname'] }}" # Note the node hostname key in here
|
|
ipmi_user: "{{ ipmi['users']['pvc']['username'] }}"
|
|
ipmi_password: "{{ ipmi['users']['pvc']['password'] }}"
|
|
cpu_tuning: # Example of cpu_tuning overrides per-node, only relevant if enabled; see below
|
|
system_cpus: 2
|
|
osd_cpus: 2
|
|
- hostname: "pvchv2" # This name MUST match the Ansible inventory_hostname's first portion, i.e. "inventory_hostname.split('.')[0]"
|
|
is_coordinator: yes
|
|
node_id: 2
|
|
router_id: "192.168.100.12"
|
|
upstream_ip: "192.168.100.12"
|
|
cluster_ip: "10.0.0.2"
|
|
storage_ip: "10.0.1.2"
|
|
ipmi_host: "{{ ipmi['hosts']['pvchv2']['hostname'] }}" # Note the node hostname key in here
|
|
ipmi_user: "{{ ipmi['users']['pvc']['username'] }}"
|
|
ipmi_password: "{{ ipmi['users']['pvc']['password'] }}"
|
|
- hostname: "pvchv3" # This name MUST match the Ansible inventory_hostname's first portion, i.e. "inventory_hostname.split('.')[0]"
|
|
is_coordinator: yes
|
|
node_id: 3
|
|
router_id: "192.168.100.13"
|
|
upstream_ip: "192.168.100.13"
|
|
cluster_ip: "10.0.0.3"
|
|
storage_ip: "10.0.1.3"
|
|
ipmi_host: "{{ ipmi['hosts']['pvchv3']['hostname'] }}" # Note the node hostname key in here
|
|
ipmi_user: "{{ ipmi['users']['pvc']['username'] }}"
|
|
ipmi_password: "{{ ipmi['users']['pvc']['password'] }}"
|
|
|
|
# Bridge device entry
|
|
# This device is passed to PVC and is used when creating bridged networks. Normal managed networks are
|
|
# created on top of the "cluster" interface defined below, however bridged networks must be created
|
|
# directly on an underlying non-vLAN network device. This can be the same underlying device as the
|
|
# upstream/cluster/storage networks (especially if the upstream network device is not a vLAN itself),
|
|
# or a different device separate from the other 3 main networks.
|
|
pvc_bridge_device: bondU # Replace based on your network configuration
|
|
pvc_bridge_mtu: 1500 # Replace based on your network configuration
|
|
|
|
# SR-IOV device configuration
|
|
# SR-IOV enables the passing of hardware-virtualized network devices (VFs), created on top of SR-IOV-enabled
|
|
# physical NICs (PFs), into virtual machines. SR-IOV is a complex topic, and will not be discussed in detail
|
|
# here. Instead, the SR-IOV mode is disabled by default and a commented out example configuration is shown.
|
|
pvc_sriov_enable: False
|
|
#pvc_sriov_device:
|
|
# - phy: ens1f0
|
|
# mtu: 9000
|
|
# vfcount: 6
|
|
|
|
# Memory tuning
|
|
# > ADVANCED TUNING: For most users, this is unnecessary and PVC will run fine with the default memory
|
|
# allocations. Uncomment these options only low-memory situations (nodes with <32GB RAM).
|
|
#
|
|
# OSD memory limit - 939524096 (~900MB) is the lowest possible value; default is 4GB.
|
|
# > This option is *only* applied at cluster bootstrap and cannot be changed later
|
|
# here, only by editing the `files/ceph/<cluster>/ceph.conf` file directly.
|
|
#pvc_osd_memory_limit: 939524096
|
|
#
|
|
# Zookeeper heap memory limit, sets Xms and Xmx values to the Java process; default is 512M.
|
|
# > WARNING: Unless you have an extremely limited amount of RAM, changing this setting is NOT RECOMMENDED.
|
|
# Lowering the heap limit may cause poor performance or crashes in Zookeeper during some tasks.
|
|
#pvc_zookeeper_heap_limit: 128M # 1/4 of default
|
|
#
|
|
# Zookeeper stack memory limit, sets Xss value to the Java process; default is 1024M.
|
|
# > WARNING: Unless you have an extremely limited amount of RAM, changing this setting is NOT RECOMMENDED.
|
|
# Lowering the stack limit may cause poor performance or crashes in Zookeeper during some tasks.
|
|
#pvc_zookeeper_stack_limit: 256M # 1/4 of default
|
|
|
|
# CPU tuning
|
|
# > ADVANCED TUNING: For most users, this is unnecessary and PVC will run fine with the default CPU
|
|
# allocations. Adjust these options only for clusters where CPU optimization is needed.
|
|
# > Defines CPU tuning/affinity options for various subsystems within PVC. This is useful to
|
|
# help limit the impact that noisy elements may have on other elements, e.g. busy VMs on
|
|
# OSDs, or system processes on latency-sensitive VMs.
|
|
# > To enable tuning, set enabled to yes.
|
|
# > Within "nodes", two counts are specified:
|
|
# * system_cpus: The number of CPUs to assign to the "system" slice, i.e. all non-VM,
|
|
# non-OSD processes on the system. Should usually be at least 2, and be
|
|
# higher on the coordinators of larger clusters (i.e. >5 nodes).
|
|
# * osd_cpus: The number of CPUs to assign to the "osd" slice, i.e. all OSD processes.
|
|
# Should be at least 1 per OSD, and ideally 2 per OSD for best performance.
|
|
# A third count, for the VM CPUs, is autogenerated based on the total node CPU count and
|
|
# the above two values (using all remaining CPUs).
|
|
# > Tuning is done based on cores; for systems with SMT (>1 thread-per-core), all SMTs within
|
|
# a given core are also assigned to the same CPU set. So for example, if the system assigns
|
|
# 2 system_cpus, there are 16 cores, and there are 2 threads per core, the list will be:
|
|
# 0,1,16,17
|
|
# leveraging the assumption that Linux puts all cores before all threads.
|
|
# > This tuning section under "nodes" is global to the cluster; to override these values on
|
|
# a per-node basis, use the corresponding "cpu_tuning" section of a given "pvc_nodes" entry
|
|
# as shown below.
|
|
# > If disabled after being enabled, the tuning configurations on each node will be removed
|
|
# on the next run. A reboot of all nodes is required to fully disable the tuning.
|
|
cpu_tuning:
|
|
enabled: no
|
|
nodes:
|
|
system_cpus: 2 # Set based on your actual system configuration (min 2, increase on coordinators if many nodes)
|
|
osd_cpus: 2 # Set based on your actual number of OSDs
|
|
|
|
# Configuration file networks
|
|
# > Taken from base.yml's configuration; DO NOT MODIFY THIS SECTION.
|
|
pvc_upstream_device: "{{ networks['upstream']['device'] }}"
|
|
pvc_upstream_mtu: "{{ networks['upstream']['mtu'] }}"
|
|
pvc_upstream_domain: "{{ networks['upstream']['domain'] }}"
|
|
pvc_upstream_netmask: "{{ networks['upstream']['netmask'] }}"
|
|
pvc_upstream_subnet: "{{ networks['upstream']['subnet'] }}"
|
|
pvc_upstream_floatingip: "{{ networks['upstream']['floating_ip'] }}"
|
|
pvc_upstream_gatewayip: "{{ networks['upstream']['gateway_ip'] }}"
|
|
pvc_cluster_device: "{{ networks['cluster']['device'] }}"
|
|
pvc_cluster_mtu: "{{ networks['cluster']['mtu'] }}"
|
|
pvc_cluster_domain: "{{ networks['cluster']['domain'] }}"
|
|
pvc_cluster_netmask: "{{ networks['cluster']['netmask'] }}"
|
|
pvc_cluster_subnet: "{{ networks['cluster']['subnet'] }}"
|
|
pvc_cluster_floatingip: "{{ networks['cluster']['floating_ip'] }}"
|
|
pvc_storage_device: "{{ networks['storage']['device'] }}"
|
|
pvc_storage_mtu: "{{ networks['storage']['mtu'] }}"
|
|
pvc_storage_domain: "{{ networks['storage']['domain'] }}"
|
|
pvc_storage_netmask: "{{ networks['storage']['netmask'] }}"
|
|
pvc_storage_subnet: "{{ networks['storage']['subnet'] }}"
|
|
pvc_storage_floatingip: "{{ networks['storage']['floating_ip'] }}"
|