Increase possible humidity offsets and fix gain
This commit is contained in:
@@ -441,7 +441,7 @@ micro_wake_word:
|
|||||||
id: mww
|
id: mww
|
||||||
microphone:
|
microphone:
|
||||||
microphone: mic
|
microphone: mic
|
||||||
gain_factor: 64
|
gain_factor: 2
|
||||||
stop_after_detection: false
|
stop_after_detection: false
|
||||||
models:
|
models:
|
||||||
- model: github://joshuaboniface/Custom_V2_MicroWakeWords/models/computer/computer.json
|
- model: github://joshuaboniface/Custom_V2_MicroWakeWords/models/computer/computer.json
|
||||||
@@ -998,7 +998,7 @@ switch:
|
|||||||
|
|
||||||
number:
|
number:
|
||||||
# Temperature offset:
|
# Temperature offset:
|
||||||
# A calibration from -30 to +5 for the temperature sensor
|
# A calibration from -30 to +10 for the temperature sensor
|
||||||
- platform: template
|
- platform: template
|
||||||
name: "Temperature Offset"
|
name: "Temperature Offset"
|
||||||
id: temperature_offset_setter
|
id: temperature_offset_setter
|
||||||
@@ -1014,12 +1014,12 @@ number:
|
|||||||
value: !lambda 'return float(x);'
|
value: !lambda 'return float(x);'
|
||||||
|
|
||||||
# Humidity offset:
|
# Humidity offset:
|
||||||
# A calibration from -20 to +20 for the humidity sensor
|
# A calibration from -50 to +50 for the humidity sensor
|
||||||
- platform: template
|
- platform: template
|
||||||
name: "Humidity Offset"
|
name: "Humidity Offset"
|
||||||
id: humidity_offset_setter
|
id: humidity_offset_setter
|
||||||
min_value: -20
|
min_value: -50
|
||||||
max_value: 20
|
max_value: 50
|
||||||
step: 0.1
|
step: 0.1
|
||||||
lambda: |-
|
lambda: |-
|
||||||
return id(humidity_offset);
|
return id(humidity_offset);
|
||||||
|
|||||||
Reference in New Issue