Increase possible humidity offsets and fix gain

This commit is contained in:
2025-10-20 00:01:14 -04:00
parent d75325198f
commit 861d1e1c4d

View File

@@ -441,7 +441,7 @@ micro_wake_word:
id: mww id: mww
microphone: microphone:
microphone: mic microphone: mic
gain_factor: 64 gain_factor: 2
stop_after_detection: false stop_after_detection: false
models: models:
- model: github://joshuaboniface/Custom_V2_MicroWakeWords/models/computer/computer.json - model: github://joshuaboniface/Custom_V2_MicroWakeWords/models/computer/computer.json
@@ -998,7 +998,7 @@ switch:
number: number:
# Temperature offset: # Temperature offset:
# A calibration from -30 to +5 for the temperature sensor # A calibration from -30 to +10 for the temperature sensor
- platform: template - platform: template
name: "Temperature Offset" name: "Temperature Offset"
id: temperature_offset_setter id: temperature_offset_setter
@@ -1014,12 +1014,12 @@ number:
value: !lambda 'return float(x);' value: !lambda 'return float(x);'
# Humidity offset: # Humidity offset:
# A calibration from -20 to +20 for the humidity sensor # A calibration from -50 to +50 for the humidity sensor
- platform: template - platform: template
name: "Humidity Offset" name: "Humidity Offset"
id: humidity_offset_setter id: humidity_offset_setter
min_value: -20 min_value: -50
max_value: 20 max_value: 50
step: 0.1 step: 0.1
lambda: |- lambda: |-
return id(humidity_offset); return id(humidity_offset);