From 66573f23465c353d55f5f1088dce12f8782d37a2 Mon Sep 17 00:00:00 2001 From: "Joshua M. Boniface" Date: Sat, 17 May 2025 00:14:02 -0400 Subject: [PATCH] Adjust Sensirion update interval 15s is a little too frequent, so make it 60s --- supersensor.yaml | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/supersensor.yaml b/supersensor.yaml index 81fc02b..b6e1f26 100644 --- a/supersensor.yaml +++ b/supersensor.yaml @@ -515,7 +515,7 @@ sensor: id: sgp30_tvoc accuracy_decimals: 1 store_baseline: yes - update_interval: 15s + update_interval: 60s - platform: sht4x temperature: @@ -528,7 +528,7 @@ sensor: id: sht45_humidity filters: - offset: !lambda return id(humidity_offset); - update_interval: 15s + update_interval: 60s - platform: absolute_humidity name: "SHT45 Absolute Humidity"